Vector VEC021AC, VEC023 owner manual Recharging, Table I. Estimated Battery Life

Page 8

8

WARNING: DO NOT RECHARGE FOR MORE THAN 3-4 HOURS MAXIMUM USING 12-VOLT DC METHOD.

1.NOTE: If unit is fully discharged, it is recommended that the vehicle being used for recharging be left running while the unit is being charged via the 12-volt DC method.

2.Insert one end of the DC/DC charging cord into the 12-volt DC cigarette lighter receptacle on the vehicle or boat. See Fig. 5 #3.

3.Insert the plug at the other end of this power cord (Fig. 5 #4) into the 12-volt DC receptacle on the front panel of the unit.

4.Charge the unit until the green CHARGED indicator is lit—DO NOT EXCEED 3-4 HOURS MAXIMUM.

5.Remove the power cord and store in a safe place.

4.3 Recharging

1.For maximum battery life, we recommend that the INDUSTRIAL 900™ system be kept fully charged at all times. If the battery is allowed to remain in a discharged state, battery life may be shortened.

Note: Recharging battery after each use will prolong battery life; frequent discharges between recharges will reduce battery life. Table I shows the relationship of the frequency of use between recharging and the expected number of discharge/recharge cycles.

TABLE I. - ESTIMATED BATTERY LIFE

AVERAGE NUMBER OF USES

POTENTIAL TOTAL NUMBER

(JUMPSTART OR DISCHARGES)

OF JUMPSTART OR DISCHARGE CYCLES

BETWEEN RECHARGES

(LIFETIME OF UNIT BATTERY)

9

5.1To Use The Industrial 900™ System As A 12-Volt DC Portable Power Supply

1.NOTE: Make sure that the unit ‘s safety ON/OFF switch is ALWAYS in the OFF position when using the 12-volt DC accessory outlet.

2.Lift up the cover of the unit ‘s 12-volt DC cigarette lighter-type receptacle.

3.Insert the 12-volt DC plug from the appliance into the receptacle on the unit.

4.Switch on the appliance, as usual.

CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 15 AMPS.

Table III shows the estimated 12-volt DC operation times when using a fully-charged system.

TABLE III. - INDUSTRIAL 900™ AS A 12-VOLT DC POWER SUPPLY

APPLIANCE TYPE

ESTIMATED POWER

ESTIMATED USAGE

 

CONSUMPTION (IN WATTS)

TIME (IN HOURS)

 

 

 

CELL PHONE

3

35

FLUORESCENT LIGHT

4

30

RADIO, FAN, DEPTH FINDER

9

21

CAMCORDER, VCR, SPOTLIGHT

15

12

POWER TOOLS, BILGE PUMP

24

7

ELECTRIC COOLER

48

3

AIR COMPRESSOR, CAR VACUUM

80

1.5

1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000+ 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700+ 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 500+

2.The time required to fully

NOTE:ALL TIMES ARE APPROXIMATE, AND BASED UPON FULLY CHARGED UNIT.

recharge the INDUSTRIAL 900™ system after jumpstarting an engine depends on how

many jumpstarts are performed between recharging sessions. Table II shows the approximate recharging times to be expected.

TABLE II. - ESTIMATED RECHARGING TIMES BASED ON NUMBER OF JUMPSTARTS (OR DISCHARGES) PERFORMED SINCE LAST FULL CHARGING

NUMBER OF

RECHARGING

NUMBER OF

RECHARGING

JUMPSTARTS

TIME (IN MINUTES)

JUMPSTARTS

TIME (IN MINUTES)

 

1

. . . . . . 8

4

32

 

2

. . . . . . 16

5

40

 

3

. . . . . . 24

6

48

 

 

 

 

 

 

 

3.Note: Check the battery charge level by depressing the PUSH FOR STATUS switch. The L.E.D. display will show the level of the battery ‘s charge.

5.2To Use The Industrial 900™ System As A 110-Volt AC Power Supply

1.IMPORTANT: Before using the unit as a 110-volt power supply, read the complete instructions, information and troubleshooting tips, pertaining to the inverter, in the back of this manual.

2.Make sure that the inverter ‘s power switch is in the OFF position before recharging or making any connection to power source or load.

3.Line up the body housing on the Vector™ Power Force 150™ inverter (sold separately for Model VEC021; included with Model VEC021AC) with the mounting walls on the back of the INDUSTRIAL 900™. Slide the inverter into place, from right to left. See Fig. (2) #4.

4.Note the convenient built-in cord storage above the inverter mounting.

5.NOTE: Once inverter is properly in place, lock-in tab button will pop up, see Fig. (2) #3 (depress tab button to release and remove inverter).

6.Remove the inverter‘s adapter cord from its storage compartment, and plug the cigarette lighter-type tip into the 12-volt DC receptacle on the front of the unit.

7.Plug the appliance‘s 110-volt plug into the corresponding socket on the inverter.

8.Turn the inverter power switch to ON.

9.Turn the appliance on, and operate as normal.

10.After use, unplug the inverter‘s adapter cord from the front of the unit and replace in the storage compartment.

Image 8
Contents 900 Table of Contents Battery Replacement Battery DisposalJumpstart System AND/OR the Power Force Inverter First AIDCHARGER/POWER Cord WORK/EMERGENCY Light ON/OFF SwitchCharge Status Button HEAVY-DUTY #4AWG HEAVY-DUTY, 600 AMP Copper ClampsFeatures Safety WarningsImportant Information First AIDUsing the Industrial 900 AS a Jumpstart System EASY, STEP-BY-STEP Jumpstarting InstructionsBattery Replacement Battery DisposalCHARGING/RECHARGING 110-Volt AC ChargingTable I. Estimated Battery Life RechargingIntroduction SpecificationsReplacement Parts Installation Troubleshooting Operating TipsProduct Specifications Troubleshooting GuideLOW Output Voltage TV, Power Tool will not Start UP LengthYear Limited Warranty Registration Form FT. LAUDERDALE, FL