QSC Audio DSP-4 DPX-1 Accessory Power Supply, Connection to accessory external power supply DPX-1

Page 12

DPX-1 Accessory Power Supply

Connection to accessory external power supply (DPX-1)

When the module is used with QSC amplifiers that do not provide +15 VDC through their DataPort connection OR is used with non-DataPort amplifiers, power must be supplied to the DSP-4 from an external power supply. All non-QSC amplifier applications require use of the DPX-1 accessory external supply. Contact QSC’s Technical Services Department or your QSC representative for more information. Any damage to the DSP-4 caused by con- nection to a non-QSC external power supply is not covered under the warranty. Use of the DPX-1 with QSC amplifiers that do provide +15VDC through the DataPort will not harm the DSP-4, although it is not necessary.

Connection to an improper voltage source can cause immediate damage to the DSP-4!

When using the external power source, we recommend that the DSP-4 be powered-up before the amplifier in order to insure trouble-free start-up. This will avoid audio “thumps & bumps”.

To connect the DPX-1 to the DSP-4 module, plug the DPX-1 power con- necter into the DSP-4’s External Power jack. Then plug the DPX-1 into the AC outlet. After the DSP-4 module has been powered up, the amplifier may be turned on.

QSC offers the DPX-1 accessory exter- nal power supply for applications with non-QSC amplifiers or with QSC Power- light models that do not provide the required operating voltage.

12

Image 12
Contents Digital Signal Processor Amplifer Accessory Hardware Manual TD-000103-00Important Safety Precautions & Explanation of Symbols Introduction Connector and Indicator Descriptions SelectableIntroduction Functions and Features Signal CompressorMultiple Delays Introduction- Block Diagram Installation Software InstallationUnpacking What else will I need?Mounting on Amplifier QSC CX, DCA, Powerlight2 Ensure all mounting screws are installed Remote mounting 4-ch., 8-ch., Powerlight & non QSC amp’s DataPort Connections XLR ConnectionsRS-232 Connection RS-232 Port ConnectionDPX-1 Accessory Power Supply Connection to accessory external power supply DPX-1Daisy Chaining Daisy chaining the DSP-4 outputs to additional amplifiersUSE- General Guidelines for Freely Configurable DSP USE- Special Information About Saving DSP-4 ConfigurationsReason Special Information About Saving DSP-4 Configurations Overall Notes and WarningsSpecifications Audio convertersPower Amplifier Connectivity Contact Closure Input senseArchitect’s and Engineer’s Specifications Pin Signal Description Description of Encode SignalsDataPort Pinout PinJumper pin 1 to Application Information Page Page How to Contact QSC Audio Products QSC Audio Products 3 Year Limited Warranty