Hardware Description (continued)
BYPASS CROSSOVER MODE Switch: The BYPASS CROSSOVER MODE switch routes the center channel input signal through the
Bypass Crossover Level Adjustment Potentiometers: These are used to adjust the characteristic of the Bypass crossover. The
DCM 10/10D | DCM 30/30D | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DCM 10/10D
Barrier Strip Screw Terminals: The barrier strip screw terminals provide connec- tions for output to an external monitor loudspeaker, subwoofer, alternate equalization switching, auxiliary input, and hearing impaired audio output.
EXTERNAL SPKR: These terminals provide the identical audio supplied to the front panel’s monitor loudspeaker. If using an external monitor loudspeaker, remover the jumper between the EXTERNAL SPKR + and IN SPR terminals. Removing this jumper disables the internal monitor loudspeaker. Any external loudspeaker used must have a minimum impedance of 4 ohms. The DCM’s internal monitor amplifier has a maximum output of 15 watts.
IN SPR: This terminal is connected to the EXTERNAL SPKR + terminal if using only the DCM’s internal monitor loudspeaker. If using an external monitor loud- speaker, remove the jumper that connects the IN SPR terminal to the EXTERNAL SPKR + terminal.
SUB OUT provides the identical audio as the subwoofer DataPort. This connection cannot be monitored or include any of the Fault Analysis functions because there are no signal return connections.
ALT EQ SELECT is a contact closure input used to activate an alternate equaliza- tion which has been created using the DCM Manager sofware. A switch or set of relay contacts may be used to activate/deactivate the alternate equalization set- tings. When the contacts are closed, the front panel ALT EQ indicator illuminates.
AUX INPUT is a single mono audio input that can be used to supply an additional channel for a ceiling speaker or other application. The aux channel can be pro- cessed as a
HEAR IMP OUT is a single mono audio output which contains a mix of the left, center, and right signals with the center signal boosted 6 dB. This is usually con- nected to a special cinema system which supplies headphone audio feeds for peo- ple with hearing difficulties. This can also be used as an input signal to a powered loudspeaker for remote monitoring of basic L/C/R signals in larger projection booths.
IEC Inlet: The power receptacle accepts a standard IEC power cable. The DCM uses a switching power supply that accepts 100 to 240 volts AC,
DCM 30/30D