Hardware Description (continued)
NOTE: The DCM 10 and DCM 10D have one output for each surround zone and 4 sub outputs.
NOTE: All combining of the individual frequency outputs
Monitor Volume: The Monitor Volume control is used to adjust the monitoring volume from the front panel loudspeaker. Rotating the control clockwise increases the volume. Rotating the control
Diagnostic Indicators: The diagnostics indicator section (including and directly below the POWER indicator) provides a simple method of ver- ifying proper system operation and performing basic troubleshooting.
The POWER LED shows whether the DCM unit is on or off.
The INPUT CLIP LED is helpful in verifying that the cinema processor is not
The LOAD FAULT indicator is a unique and powerful feature which verifies that signal inputs into the DCM actually make it through the DCM, the DataPort cables, and the amplifier unit all the way to the loudspeakers, and that the loudspeaker connections are not electrically shorted or open. All of these measurements are being performed constantly (without user action) on ALL output channels and any unusual readings will light the Load Fault LED. If the Load Fault LED is lit, pressing the Amps/Proc button (and holding it pressed) will cause the prob- lem channel’s indicator LED to blink. This information will let you inspect the system cabling for that channel and troubleshoot the problem.
LOAD FAULT indicator note: The DCM’s Load Fault detection scheme uses a complex averaging algorithm which compares input sig- nals to output signals and measures voltage and current on all amplifier outputs. To sense real world conditions, these measurements must be found to be “out of range” several times before the Load Fault condition is indicated on the front panel. If you are simulating fault conditions, you MUST have a
The ALT EQ indicator is lit when the alternate equalization settings are enabled by the ALT EQ SELECT contact closure terminals on the rear panel.
REMEMBER: If you configured the DCM Manager software to not have certain channels (for example there is no SUB 3 or SUB 4) or have not assigned a QSC amplifier to a channel, these channels WILL NOT indicate any faults.
Test Jacks: The test jacks provide the signal being sent to the front panel loudspeaker
BYPASS Switch: If there’s a problem with the DCM or system cabling, the DCM active circuitry can be bypassed, routing audio to the center channel.
In the NORMAL position, the DCM performs normal monitor and crossover func- tions.
In the BYPASS position, the PROC center channel signal is routed to a crossover, and then to the center channel amplifier. On the rear panel, there is a BYPASS CROSSOVER MODE select switch and equalization band level adjustment potenti- ometers for precisely setting bypass mode audio.
NOTE: The switch is recessed and can be operated by using an appropriately sized tool (small flat tip screwdriver, tip of ballpoint pen).