Omega Speaker Systems DPS3301 manual Program Controller Mode, Display Time, Display Option

Page 10

'PROGRAM CONTROLLER' MODE

Display Time

On entering Program Controller mode, the very first step lets you program is the display time. This determines the length of time (in seconds) that any VALUE is displayed before message, such as ‘PROCESS’ is flashed.

The unit will first show 'dSPLy t' (for Display Time), and then the

current setting in seconds. Use ‘^DIGv’ and ‘<DIG>’ key to set the desired display time. Push ‘SETUP’ key following the selection.

Display Option:

This is indicated by the display briefly reading 'dSP OPt' (for display option) and then the currently selected Option. Use ‘^DIGv’ key to step thru various options. Once the desired option has been selected, push ‘SETUP’ key to enter it and go on to set Display Time.

Display Mode

Display shows

Description

PROCESS

PrOCESS

Displays process value.

SETPOINT DEVIATION

SP. DEVN

Displays setpoint deviaition.

INSTANTANEOUS RATE

In. rAtE

Displays Instantaneous rate value.

PROCESS HIGH

Pr. HIGH

Displays process’ highest reading

PROCESS LOW

Pr. LO

Displays process’ lowest reading

ELAPSED TIME

ELPSd. T

Displays elapsed time.

TIMER 1 COUNT DOWN

tr1. Cnt

Display Timer 1 count down value

TIMER 2 COUNT DOWN

tr1. Cnt

Display Timer 2 count down value

SCAN

SCAn

Scans through all the above parameters

Rate Time-Base:

This step is for programming time-base for calculation of Rate. Units of time-base are seconds. Again, the active digit will be flashing. Message displayed before the value is “rATE tb:. To change the value, push ^v key. To activate another digit for change, use <DIG> key. On finishing, push SETUP key.

Page 10

Image 10
Contents DPS3301 Series Wall-MountProgrammable Temperature Monitor Specifications Description Thermocouple or RTD Selection Timers Specifications AccuracyDescription Thermocouple or RTD SelectionHow to Reset and Program Thermocouple Type or RTD Display ModesDisplay Units C/F Retaining User Settings on Power DownDisplay Hold Feature Setpoint DeviationFlow Chart Program LimitsHow To Increase/Decrease Programmable Values Setup Setup ModeEntering and Exiting Setup Mode Passcode EntryDisplay Option Program Controller ModeDisplay Time Rate Time-BaseCold Junction adjustment Thermocouple CalibrationProcess Limits 1 thru ‘PROGRAM LIMITS’ ModeThermocouple type Selection Selection of Limit 3 as Process or Rate LimitProgramming Limit Configure Timing ModeSelection of Limit 4 as Process or Deviation Relay Deadband Timers 1Configuring Limits Normally Open/Normally Closed Relay Latching/non LatchingRate Alarm Setpoint Deviation AlarmAudio Alarm On/Off Resetting Rate AlarmProcess Alarms Timers Open Collector OptionTimer Modes Elapsed TimeHow to Reset High & Low Peak readings PowerSignal Connection High and LOW PeaksOutput Connector PIN Assignment Output Connector Pin AssignmentDPS3301 Series Terminal Compartment Direct Interface to Universal Relay Module Mounting Page Page M4300/0907