Omega Vehicle Security DPS3300 manual Specifications

Page 4

SPECIFICATIONS

(Typical @ 25C and rated supply voltage unless otherwise specified)

STANDARD INPUTS

*4-20ma 0-50ma 0-5Vdc 0-10Vdc

*Thermocouple inputs: J, K, T, E, R, S, and B

*Cold junction compensation error: +/- 1C (10C to 40C)

*Open input indication: HELP displayed

*Temperature displayable in Degrees C or F

*Non-standard inputs available --- consult factory.

ANALOG TO DIGITAL CONVERSION

*4-1/2 Digit (20,000) Count) A/D Converter

*Dual slope integrating converter with 7 conversions /sec. (typical) rate.

SCAN RATE

* Fixed: two channels per second

DISPLAY

*Red seven segment displays--0.8" (20mm) digit height

*Over range indication: HELP

*Display test: Briefly displays 8.8.8.8.8.8.8 on power up.

*Seven-digit display

SCALE/OFFSET

*Scale programmable from 1 - 30000 units

*Offset programmable from 0 - 99.99mA (For mA Input)

*Offset programmable from 0 - 9.999V (For Voltage Input)

*Programmable decimal point.

RELIABILITY/ACCURACY

*Calibration: NIST traceable (for thermocouples)

*Temperature resolution: 1C/1F

*Warranty: 1 Year

*Recalibration recommended at 12-month interval

POWER REQUIREMENT

 

* 120Vac --- 60 HZ

(Standard)

* 240Vac --- 50 HZ

(optional)

* 15VDC

(optional)

OUTPUT (optional)

*Open collector outputs -- 50ma maximum sink, limited to 50ma per output

*Relays: Single pole single throw, 1 Amp @ 28Vdc or 0.5 Amp @ 120Vac resistive *Output termination: Euro-style plug-in connector

Page 3

Image 4
Contents Wall mount Multi-Channel Process Scanner Setup Channel ConfigurationSystem Configuration Display ModesTable of Contents Power Input Connector PIN AssignmentDirect Interface to Universal Relay Module Trouble Shooting Error Messages and Solutions MountingSpecifications Page Description Model no DescriptionDisplaying Parameters How to Display ParametersTo Display Perform Following Steps Mode Function Performed Elapsed Time ModeDisplay Modes Scan Mode High/Low Channel ModeSetup Deviation ModeDifference Mode Types of Deviation DisplaysCH Parameter List SYS Parameter ListChannel Configuration Setup for Voltage or Current InputSetup For Input Type Setup For Channel ON/OFFSetup For High Scale Setup For Low ScaleSetup For Offset Setup For TareSetup For Setpoint Setup for Universal Relay Channel 1 RelaySetup For Limits Setup For DeadbandSetup for Thermocouple/ Thermistor/ RTD Inputs Setup For Engineering UnitsTemperature units Turning Channels ON/OFFSetup Examples System ConfigurationSetup For Display Options Setup For Display Time Setup For Relay Latch/Non-LatchSetup for Buzzer Setup For Cold Junction CalibrationInput Range Setup for current and voltage Setup For Channel CalibrationThermocouple Calibration Procedure Saving Parameter PeaksPage Enter Passcode SYS CHSelect Channel Channel DiffElapsed Time IP Type Scan High Channel LOW Channel Display Devn Channel DiffThermistor CR.AL T/C K CurrentRate LimitsOutputs Open Collector OptionInput Connector Output Connector Power Input Connector PIN AssignmentDirect Interface to Universal Relay Module Direct Serial Interface toError Messages and Solutions Trouble ShootingFactory Channel settings Mounting Slots in Terminal Compartment For Mounting ScrewsWarranty Page M4302/0306