Omnitron Systems Technology user manual Updating the 2GXM Firmware via the Serial Console Port

Page 21

PI

SA

IP and Control Preferences Screen

iConverter, Serial Agent

1:

Set IP

 

192.168.1.220

2:

Set Subnet Mask

255.255.255.0

3:

Set Gateway

192.168.1.1

4:

Chassis Number

1

5:

Chassis Name (also sysName)

2GXM

6:

Enable/Disable TELNET

Enabled

7:

Enable/Disable FTP

Disabled

8:

Enable/Disable Soft Switch Reload

Disabled

9:

TELNET Password

*****

10: FTP

Password

 

11: Serial Password

 

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >6

Disable TELNET (Y/N)?>

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

The 2GXM may be accessed and configured via Telnet using any standard Telnet client. Only one Telnet session can be active at a time. An inactive Telnet session terminates automatically after 5 minutes.

3.4.5.3Updating the 2GXM Firmware via the Serial Console Port

To update the 2GXM firmware from the Serial Console Port, select 10 at the Management Options screen, press <ENTER>. The 2GXM will display the following:

PI

SA

Management Options

iConverter, Serial Agent

Network Management

1:Chassis and Module Management

2:Set Module Identifier

Management Module Preferences

3:IP and Control Preferences

4:SNMP Preferences

5:Abandon Preference Changes

6:Save Preference Changes

7:Restore to Factory Defaults

8:Restart Management Module

9:Other Networking Features

Management Module Maintenance

10:Firmware Update

11:Set Date/Time

IP Address

= 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 10

UPDATE: Are you sure? (Y/N) > Y

Please Xmodem file now:

From the terminal program, use the Xmodem protocol to send the new 2GXM-xxx.bin firmware file to the 2GXM module (where xxx represents the release level of the software).

Once the file transfer begins, the data uploads to the 2GXM. The process takes about five minutes over a serial connection.

Page 21

Image 21 Contents
Standalone and PLUG-IN Module Table of Contents Standalone Plug-In OverviewPort Structure Installation Procedure Configuring DIP-SWITCHES DIP-switch Bank 2 is only available on the plug-in module 2.3 SW3 Pause Disable/Enable Off/On Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2GXM Setting the Chassis Number and Name Setting 2GXM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the 2GXM Remotely Updating the 2GXM Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2GXM LED Module Management Mode Port Configuration Port Access 3 802.3ah Parameters Local Status Section OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid Vlan ID VID BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2GXM SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty