Omnitron Systems Technology 2GXM user manual Oui

Page 31

the remote ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs network frames to the higher sublayer. If “Loopback” is displayed, the remote partner is looping back non- OAMPDUs network frames. If “Discard” is displayed, the remote partner is discarding non-OAMPDUs network frames. If “Unknown”, the Parser Action state of the remote partner is indeterminate.

Critical Event - Indicates the Critical Event state (“Yes”, “No” or “Unknown”) of the remote partner. If “Yes” is displayed, the local device has detected a Critical Event. If “No”, the local device has not detected a critical event. If “Unknown,” the Critical Event status of the remote partner is indeterminate.

Link Fault - Indicates the remote partner has detected a fault in the receive direction (“Yes”, “No” or “Unknown”). If “Yes” is displayed, the receive link is down. If “No”, the receive link is up. If “Unknown,” the link fault status is indeterminate.

OAM Mode - Indicates the OAM mode (“Active” or “Passive”) of the remote partner.

Supports - Indicates the supported options (Variable Access “Var”, Link Event Notification “Event”, Loopback “LB”, or blank if no options are supported) of the remote partner.

OUI - Indicates the three hex byte IEEE organizational specific identifier (or blank if unknown) of the remote partner.

802.3ah parameters can be accessed by selecting options 7 from the Port configuration screen. The fiber (port 1) configuration screen is displayed.

PI

SA

802.3ah Control - iConverter 2GXM

iConverter, Serial Agent

Identifier -

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8999-0

Port # = 1

1: 802.3ah OAM State

 

Disabled

Local Status

 

2: OAM Mode

 

Passive

Discovery State

Disabled

3: Loopback Mode

 

Disabled

Multiplexer State

Forward

4: Loopback Timeout

 

30 sec

Parser Action

Forward

5: Unidirectional Mode

Not Available

 

 

 

 

Remote Status

 

 

 

 

Discovery State

Unknown

 

 

 

Critical Event

No

 

 

 

Link Fault

No

 

 

 

Multiplexer State

Unknown

 

 

 

Parser Action

Unknown

 

 

 

Mode

Unknown

 

 

 

Supports

Unknown

 

 

 

OUI:

Unknown

Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >

To configure the 802.3ah parameters for the Port 2, type an n and press <ENTER>.

Page 31

Image 31 Contents
Standalone and PLUG-IN Module Table of Contents Standalone Plug-In OverviewPort Structure Installation Procedure Configuring DIP-SWITCHES DIP-switch Bank 2 is only available on the plug-in module 2.3 SW3 Pause Disable/Enable Off/On Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2GXM Setting the Chassis Number and Name Setting 2GXM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the 2GXM Remotely Updating the 2GXM Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2GXM LED Module Management Mode Port Configuration Port Access 3 802.3ah Parameters Local Status Section OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid BP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2GXM SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty