Omega Vehicle Security LVCN700 Series warranty Introduction, Technology, Step Two, Step Three

Page 3

INTRODUCTION

Step Two

About this Manual: PLEASE READ THE ENTIRE MANU- AL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on the LVCN700 series Ultrasonic Level Switch. Please refer to the part number located on the switch label to verify the exact model con- figuration which you have purchased.

User’s Responsibility for Safety: Omega manufactures a broad range of level sensing technologies. While each of these sen- sors is designed to operate in a wide variety of applications, it is the user’s responsibility to select a sensor model that is appropriate for the application, install it properly, perform tests of the installed sys- tem, and maintain all components. The failure to do so could result in property damage or serious injury.

Proper Installation and Handling: Only properly trained staff should install and/or repair this product. Install the switch with the included Viton gasket and never overtighten the switch within the fitting. Always check for leaks prior to system start-up.

Wiring and Electrical: A supply voltage of 95-250 VAC is used to power the Ultrasonic switch, and a supply voltage of 12-28 VDC is used to power the optional DC version of the LVCN700 series Ultrasonic switch. Electrical wiring of the switch should be performed in accordance with all applicable national, state, and local codes.

Material Compatibility: The LVCN700 series enclosure is made of a flame retardant Polycarbonate (PC/ABS FR). The trans- ducer is made of Polyvinylidene Fluoride (PVDF). Make sure that the model which you have selected is chemically compatible with the application media.

Enclosure: While the LVCN700 series housing is liquid-resis- tant, the unit is not designed to be operational when immersed. It should be mounted in such a way that the enclosure and transduc- er do not come into contact with the application media under nor- mal operational conditions.

Make a Fail-Safe System: Design a fail-safe system that accommodates the possibility of switch and/or power failure. OMEGA recommends the use of redundant backup systems and alarms in addition to the primary system.

Flammable, Explosive or Hazardous Applications:

The LVCN700 series should not be used within classified haz-

Warning

Always use the Viton gasket when installing the Ultrasonic switch, and make sure that all electrical wiring of the switch is in accordance with applicable codes.

TECHNOLOGY

Step Three

A. Application: The general purpose ultrasonic level switch pro- vides non-contact level detection up to 26’ or 8m with 3 relays. Each relay can be configured on a single set point alarm, two latched set points for automatic fill or empty, two set points for out of bounds alarms or three set point (relays 1 and 2 only) alternation / duplexing

. The switch is well suited for a wide range of corrosive, waste and slurry type media, and is broadly selected for atmospheric day tank, pump lift station and waste sump applications.

B. Part Number: The part and serial numbers are located on the wrench flat. Check the part number on the product label and confirm which of the below model configurations you have purchased:

Part Number

Range

Supply

Mount

LVCN704

4’ (1.2m)

95-250 VAC

1” NPT

LVCN704G

4’ (1.2m)

95-250 VAC

1” NPT

 

 

 

 

LVCN704-DC

4’ (1.2m)

12-28 VDC

1” NPT

LVCN704G-DC

4’ (1.2m)

12-28 VDC

1” NPT

LVCN709

9.8’ (3m)

95-250 VAC

1” NPT

LVCN709G

9.8’ (3m)

95-250 VAC

1” NPT

 

 

 

 

LVCN709-DC

9.8’ (3m)

12-28 VDC

1” NPT

LVCN709G-DC

9.8’ (3m)

12-28 VDC

1” NPT

LVCN716

16.4’ (5m)

95-250 VAC

1” NPT

LVCN716G

16.4’ (5m)

95-250 VAC

1” NPT

 

 

 

 

LVCN716-DC

16.4’ (5m)

12-28 VDC

1” NPT

LVCN716G-DC

16.4’ (5m)

12-28 VDC

1” NPT

LVCN726

26.2’ (8m)

95-250 VAC

2” NPT

LVCN726G

26.2’ (8m)

95-250 VAC

2” NPT

 

 

 

 

LVCN726-DC

26.2’ (8m)

12-28 VDC

2” NPT

LVCN726G-DC

26.2’ (8m)

12-28 VDC

2” NPT

 

 

 

 

C. NEMA 4X Enclosure: The enclosure has a flip cover with two 1/2” NPT female conduit ports and an internal terminal strip for wiring. To open the enclosure, you will need a small insertion tool such as a screwdriver. Insert the tool into the hole located at the front of the enclosure and gently push on the latching mechanism to release the cover. Rotate the hinged cover up for 135° access to the faceplate and terminal strips. Before closing the enclosure, make sure that the enclosure gasket is properly seated, and that any conduit fittings, cable connectors or plugs are installed correctly and sealed.

LVCN726

 

 

Shown

 

L1 L2

 

 

RELAY

RELAY

RELAY POWER

1

2

3

 

Cal.

Run

High

 

Low

 

Select

Image 3
Contents User’s Guide Enclosure Side View SpecificationsStep One LVCN700 Series Enclosure Top ViewStep Three IntroductionTechnology Step TwoCalibration PreparationTances, the product is held ProgrammingStep Six Holder. Alternatively, you mayTarget. Make sure that the switch is stationary and perpen That the switch is stationary and per Dicular to the target before continuingPress Select to program relay channel Installation Step Twelve Programming Duplex Pump ControlStep Thirteen Relay LED Changes State, But Relay Doesn’t Change WiringTroubleshooting Step FourteenOperation

LVCN700 Series specifications

The Omega Vehicle Security LVCN700 Series represents a significant advancement in automotive security technology, designed to provide vehicle owners with peace of mind through innovative features and comprehensive protection. This cutting-edge system is engineered to deter theft, safeguard valuable assets, and enhance the overall security profile of vehicles.

One of the main features of the LVCN700 Series is its state-of-the-art motion detection system. Utilizing advanced sensors, the system can monitor any movement around the vehicle, effectively alerting owners to potential threats. This feature is particularly beneficial in urban areas where vehicle theft is more prevalent, providing an added layer of security while parked.

The LVCN700 Series also incorporates a unique two-way communication system, allowing users to receive real-time alerts and notifications directly to their smartphones. This feature not only keeps vehicle owners informed of any suspicious activity but also allows remote control over certain functionalities, such as locking or unlocking doors, from virtually anywhere.

Additionally, the system includes a GPS tracking feature, enabling owners to locate their vehicle at any time. In the unfortunate event of theft, this technology aids law enforcement agencies in retrieving stolen vehicles more quickly and efficiently, thereby significantly increasing the chances of recovery.

Another important characteristic of the Omega LVCN700 Series is its comprehensive alarm system, which includes multiple sensors and programmable settings. Owners can customize alarm triggers based on their preferences, ranging from door openings to vibrations and glass breakage. This level of customization ensures that the system can adapt to a variety of threat levels and environments.

Furthermore, the LVCN700 Series is designed with user-friendliness in mind. Its interface is intuitive, allowing users to easily navigate settings and understand system status. Installation is also straightforward, making it accessible for both professional installers and DIY enthusiasts alike.

In summary, the Omega Vehicle Security LVCN700 Series combines cutting-edge technologies with user-friendly features to create a robust security system for today’s vehicles. With its motion detection, two-way communication, GPS tracking, and customizable alarm settings, the LVCN700 Series is a formidable solution for anyone looking to enhance their vehicle’s security and protect their investment effectively.