Siemens FX300 manual Error messages, Error message Cause Measure

Models: FX300

1 80
Download 80 pages 7.94 Kb
Page 46
Image 46

6OPERATION

6.4 Error messages

SITRANS FX300

Error message

Cause

Measure

 

 

 

No Signal

No signal from vortex amplifier

Check connector

 

 

In the event of measuring sensor

 

 

problems contact service.

 

 

 

Low freq

Sample frequency too low

Contact service.

 

 

 

High Freq

Sample frequency too high

Contact service.

 

 

 

Low Flow

Flow rate less than the set minimum

Signal converter continues to display the

 

flow rate qmin

current flow rate but the accuracy of the

 

 

measurement may be affected.

Q too high

Flow rate higher than the set maximum

Corrective measures depend on the

 

flow rate qmax

application!

 

 

If the flow rate exceeds the maximum

 

 

value, the measuring sensor may be

 

 

physically damaged.

 

 

 

Inv. Config.

Invalid configuration data in FRAM

Check entire configuration!

 

(permanent memory)

Contact service if error message

 

 

persists.

 

 

 

Amp. Fail

Error in the pre-amplifier stage

Contact service.

 

 

 

Chk. Instal.

Quality of the vortex signal too poor

1. Check qmin

 

 

2. Excessive pipe vibration and faulty

 

 

flow profile

 

 

 

Low Signal

Amplitude of vortex signal is too low

1. qmin ok?

 

 

2. If qmin OK, contact service

Hi. Signal

Amplitude of vortex signal is too high

Occurs with media of high density

 

 

1. Check qmax

 

 

2.If qmax OK, contact service

L.Temp.Phy

Operating temperature lower than

Take corrective measures within

 

specified

process.

 

 

 

H.Temp.Phy

Operating temperature higher than

Take corrective measures within

 

specified

process as quickly as possible,

 

 

otherwise both the measuring sensor

Hi.P.Phys

Pressure higher than specified

and the signal converter may be

 

 

damaged.

 

 

 

Tsens Shrt.

Temperature sensor short circuit

Shows error at temperature sensor!

 

 

Contact service.

Tsens Open

Open temperature sensor

 

 

 

 

P. Sen. Fail

Faulty pressure sensor

Displays error at pressure sensor!

 

 

Contact service.

Table 6-8: Error messages

 

46

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Page 46
Image 46
Siemens FX300 manual Error messages, Error message Cause Measure