TECHNICAL DATA 8

 

SITRANS FX300

 

 

 

8.4 Flow tables

Measuring ranges

Size

 

Qmin

 

Qmax

Qmin

 

Qmax

DN

 

NPS

 

[m3/h]

 

[gph]

EN 1092-1

 

ASME B16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

15

½

0.45

5.0

119

1321

 

 

 

 

 

 

25

1

0.81

11.40

214

3012

 

 

 

 

 

 

40

2.04

28.57

539

7547

 

 

 

 

 

 

50

2

3.53

49.47

933

13069

 

 

 

 

 

 

80

3

7.74

108.37

2045

28629

 

 

 

 

 

 

100

4

13.30

186.21

3514

49192

 

 

 

 

 

 

150

6

30.13

421.86

7960

111445

 

 

 

 

 

 

200

8

52.66

792.42

13911

209335

 

 

 

 

 

 

250

10

90.5

1266.8

23908

334653

 

 

 

 

 

 

300

12

113.41

1839.8

29960

486024

 

 

 

 

 

 

 

 

 

 

Values based on water at 20°C / 68°F

 

 

 

 

 

 

Air

15

½

6.79

32.56

1794

8602

 

 

 

 

 

 

25

1

10.20

114.0

2695

30116

 

 

 

 

 

 

40

25.35

326.63

6697

86287

 

 

 

 

 

 

50

2

43.89

565.49

11595

149388

 

 

 

 

 

 

80

3

96.14

1238.60

25398

327207

 

 

 

 

 

 

100

4

165.19

2128.27

43639

562236

 

 

 

 

 

 

150

6

374.23

4821.57

98862

1273738

 

 

 

 

 

 

200

8

702.95

9056.8

185700

2392553

 

 

 

 

 

 

250

10

1123.7

14478

29685

3824683

 

 

 

 

 

 

300

12

1632.1

21028

431155

55550104

 

 

 

 

 

 

 

 

Values based on air at 20°C / 68°F and 1.013 bar abs / 14.891 psig

 

 

 

 

 

 