6 OPERATION

 

 

 

 

 

 

 

 

 

SITRANS FX300

 

 

 

 

 

 

 

 

 

 

 

 

Level

Designation

Selection / entry

Explanation

 

 

 

 

 

 

 

 

 

(available if Maes.Inst =

kg

 

Select totalizer unit for mass flow measurement

 

 

 

Mass, see menu item

Unit ...^

 

 

 

 

1.1.3)

 

 

 

 

 

 

 

 

0000000000

Enter preset totalizer value

 

 

 

 

 

 

 

 

 

kg ......^

 

 

 

 

 

 

Reset yes /

Reset totalizer /

 

 

 

 

 

Reset no

...^

Do not reset totalizer/

 

 

 

 

 

 

 

 

 

 

Disp. off /

Display totalizer /

 

 

 

 

 

Disp. on

...^

Do not display totalizer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3

 

 

 

 

HART settings

 

 

 

 

 

 

 

 

3.3.1

Poll. Adr.

000

 

Enter HART polling address for "Multidrop operation"

 

 

 

0 – 15

 

 

 

 

 

 

 

→↑...→↑...^

 

 

 

3.3.2

HART SV

Total Flow ^

HART secondary variable

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3.3

HART TV

Temp. ^

HART tertiary variable

 

 

 

 

 

 

 

 

 

Density ^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3.4

HART 4V

Density ^

HART quaternary variable

 

 

 

 

 

 

 

 

 

Temp. ^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.4

 

 

 

 

Set fluid and medium

 

 

 

 

 

 

 

 

3.4.1

Fluid 1

 

 

Set fluid type

 

 

 

 

 

 

 

 

 

Gas ...

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid. ...

Liquid

 

 

 

 

 

 

 

 

 

 

 

Steam ...^

Steam

 

 

 

 

 

 

 

 

3.4.2

Medium

 

 

Set medium

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(available if Fluid = Gas or

Custom ...

Customer medium

 

 

 

Liquid, see menu item

 

 

 

 

 

 

3.4.1)

 

 

 

 

 

 

 

 

 

 

 

 

(available if Fluid = Steam,

Sat.Steam ...^

Saturated steam

 

 

 

see menu item 3.4.1)

 

 

 

 

 

 

Custom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Density check

 

 

 

 

 

 

 

 

 

 

 

 

3.5

 

 

 

 

Set pressure, temperature and density

 

 

 

 

 

 

 

 

3.5.1

T-sensor

 

 

Internal temperature sensor

 

 

 

 

 

 

 

 

 

No ...

 

No temperature sensor available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes ...^

Temperature sensor available

 

 

 

 

 

 

 

 

3.5.3

Sat.P/T

 

 

Density calculation for saturated steam

 

 

 

 

 

 

 

 

 

Sat. T ^

 

Density calculation for saturated steam with the

 

 

 

(verfügbar wenn FLUID =

 

 

 

 

 

saturated temperature

 

 

 

DAMPF, siehe Menüpunkt

 

 

 

 

3.4.1)

 

 

 

 

 

 

3.5.4

Temp. Opr.

 

 

Operating temperature

 

 

 

 

 

 

 

 

 

°C

 

Set temperature unit

 

 

 

 

 

 

 

 

 

 

Unit ...^

 

 

 

 

 

 

 

 

 

 

 

 

0000000.0

Operating temperature

 

 

 

 

 

°C ^

 

 

 

 

 

 

 

Disp. on /

Display temperature /

 

 

 

 

 

Disp. off

...^

Do not display temperature

 

 

 

 

 

 

 

 

 

52

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

Page 52
Image 52