OPERATION 6

 

SITRANS FX300

 

 

 

Level

Designation

Selection / entry

Explanation

 

 

 

 

 

3.5

 

 

 

Pressure, temperature and density

 

 

 

 

 

3.5.1

T-sensor

 

 

Internal temperature sensor

 

 

 

 

 

No ...

No temperature sensor available

 

 

 

 

 

 

 

 

 

Yes

...^

Temperature sensor available

 

 

 

 

 

3.5.2

P-sensor

 

 

Pressure sensor

 

 

 

 

 

Intern ...

Internal pressure sensor

 

 

 

 

 

 

 

 

 

---

...^

No pressure sensor available

 

 

 

 

 

 

 

 

 

3.5.4

Temp. Opr.

 

 

Operating temperature

 

 

 

 

 

°C

...^

Set temperature unit

 

 

 

 

Unit

 

 

 

 

 

 

 

0000000.0

Operating temperature

 

 

°C ^

 

 

 

Disp. on /

Display temperature /

 

 

Disp. off ...^

Do not display temperature

 

 

 

 

 

3.5.5

Pres. Opr.

 

 

Operating pressure

 

 

 

 

 

Pa

...^

Set pressure unit

 

 

 

 

Unit

 

 

 

 

 

 

 

0000000.0

Operating pressure

 

 

Pa ^

 

 

 

 

 

 

 

Disp. on /

Display pressure /

 

 

Disp. off ...^

Do not display pressure

 

 

 

 

 

3.5.6

Dens. Opr.

 

 

Density at operating pressure and operating

 

 

 

 

temperature

 

 

 

 

 

 

kg/m3

Set density unit

 

 

Unit

...^

 

 

 

 

 

 

 

00011.0000

Operating density

 

 

kg/m3 ^

 

3.5.7

Temp.Norm .

00000020.0

Enter normal temperature

 

(available if Maes.Inst =

°C ......^

Unit as 3.5.4

 

Norm. Vol., see menu

 

 

 

 

item 1.1.3)

 

 

 

3.5.8

Pres.Norm

00000000.0

Enter normal pressure

 

(available if Maes.Inst =

Pa ......^

Unit as 3.5.5

 

Norm. Vol., see menu

 

 

 

 

item 1.1.3)

 

 

 

3.5.9

Dens. norm

00001.2900

Enter density for reference conditions (pressure and

 

(for unknown gases using

kg/m3 ^

temperature)

 

standard volume flow

 

 

 

 

measurement, see menu

 

 

 

 

items 1.1.3, 3.4.1 and

 

 

 

 

3.4.2)

 

 

 

 

 

 

 

3.5.10

P-Excit. V

0005.00000

Exciting voltage of pressure sensor

 

(available if P-Sensor =

V ^

 

 

 

Internal, see menu item

 

 

 

 

3.5.2)

 

 

 

 

 

 

 

 

3.5.11

P-Sen.P1V1

 

 

Pressure sensor:

 

(available if P-Sensor =

 

 

1st calibration point

 

Internal, see menu item

 

 

 

 

0001.00000

 

 

3.5.2)

 

 

P1 kg/cm2g ...

 

 

 

 

 

 

...^

 

 

 

 

 

 

 

0002.00000

 

 

 

V1 mV ......^

 

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

61

Page 61
Image 61