3 INSTALLATION

 

 

 

 

 

 

SITRANS FX300

 

3.6.3 Installing devices in sandwich design

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3-13: Installation using centering ring

1Measuring sensor

2Centering ring

3Bolts with fixing nuts

4Hole

5Hole

6Gasket

• Push the first bolt 3 through the hole 5 of both flanges.

Screw on the nuts and washers to both ends of the bolt 3 but do not tighten them.

Install the second bolt through the holes 4.

Place the measuring sensor 1 between the two flanges.

Insert the gaskets 6 between measuring sensor 1 and flanges and align them.

Check that the flange is concentric.

Install the remaining bolts, washers and nuts. Do not yet tighten the nuts.

Turn the centring ring 2 in a counter-clockwise direction and align the device.

Check that the gaskets 6 are concentric; they must not protrude into the pipe cross-section.

Now tighten all nuts bit by bit alternately across the diagonal.

30

www.siemens.com/flow

06/2009 - SFIDK.PS.050.F2.02 A5E02100423