TECHNICAL DATA 8

 

SITRANS FX300

 

 

 

Process connections

Flange version

 

 

 

DIN EN 1092-1

DN15...300 in PN16…100

 

 

ASME B16.5

½...12" in 150…600 lbs

 

 

JIS B 2220

DN15...300 in JIS 10…20 K

 

 

 

For detailed information on combination flange/pressure rating,

 

refer to chapter "Dimensions and weights".

 

 

Sandwich version

 

 

 

DIN

DN15...100 in PN100 (higher pressures on request)

 

 

ASME

½...4" in 600 lbs (higher pressures on request)

 

 

JIS

DN15...100 in 10…20 K (higher pressures on request)

 

 

Electrical connections

Power supply

Non-Ex: 14…36 VDC

 

 

 

Ex: 14…30 VDC

 

 

Current output

 

 

 

Description of the used

Uext = external voltage; RL = load + resistance

abbreviations

 

Measuring range

4...20 mA (max. 20.8 mA) + HART® protocol

Load

Minimum 0 Ω; maximum RL = ((Uext. - 14 VDC) / 22 mA)

 

 

Error signal

Acc. to NAMUR NE43

 

 

 

Upper value: 21.0 mA

 

 

 

Lower value: 3.6 mA (not with HART® protocol)

Pulse output

 

 

 

Pulse rate

Max. 0.5 pulse/s (corresponds to 1800 pulses/hour)

 

 

Power supply

Non-Ex: 24 VDC as NAMUR or open < 1 mA, maximum 36 V, closed

 

100 mA, U < 2 V

 

 

 

Ex: 24 VDC as NAMUR or open < 1 mA, maximum 30 V, closed 100 mA,

 

U < 2 V

 

 

HART®

 

 

HART® protocol via current output

Device revision

1

 

 

Physical layer

FSK

 

 

Device category

Transmitter, galvanically isolated

 

 

System requirements

Load min. 250 Ω

 

 

Multidrop operation

4 mA

 

 

Approvals and certifications

ATEX

ATEX II 2G EEx d ia [ia] IIC T6

 

 

FM

Class I, II, III

 

Div 1/2, groups A-G

 

 

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

69

Page 69
Image 69
Siemens FX300 manual Process connections, Electrical connections, Approvals and certifications