| TECHNICAL DATA 8 |
| SITRANS FX300 | |
|
|
|
Process connections
Flange version |
|
|
|
DIN EN | DN15...300 in PN16…100 |
|
|
ASME B16.5 | ½...12" in 150…600 lbs |
|
|
JIS B 2220 | DN15...300 in JIS 10…20 K |
|
|
| For detailed information on combination flange/pressure rating, |
| refer to chapter "Dimensions and weights". |
|
|
Sandwich version |
|
|
|
DIN | DN15...100 in PN100 (higher pressures on request) |
|
|
ASME | ½...4" in 600 lbs (higher pressures on request) |
|
|
JIS | DN15...100 in 10…20 K (higher pressures on request) |
|
|
Electrical connections
Power supply | |
|
|
| Ex: 14…30 VDC |
|
|
Current output |
|
|
|
Description of the used | Uext = external voltage; RL = load + resistance |
abbreviations |
|
Measuring range | 4...20 mA (max. 20.8 mA) + HART® protocol |
Load | Minimum 0 Ω; maximum RL = ((Uext. - 14 VDC) / 22 mA) |
|
|
Error signal | Acc. to NAMUR NE43 |
|
|
| Upper value: ≥ 21.0 mA |
|
|
| Lower value: ≤ 3.6 mA (not with HART® protocol) |
Pulse output |
|
|
|
Pulse rate | Max. 0.5 pulse/s (corresponds to 1800 pulses/hour) |
|
|
Power supply | |
| 100 mA, U < 2 V |
|
|
| Ex: 24 VDC as NAMUR or open < 1 mA, maximum 30 V, closed 100 mA, |
| U < 2 V |
|
|
HART® |
|
| HART® protocol via current output |
Device revision | 1 |
|
|
Physical layer | FSK |
|
|
Device category | Transmitter, galvanically isolated |
|
|
System requirements | Load min. 250 Ω |
|
|
Multidrop operation | 4 mA |
|
|
Approvals and certifications
ATEX | ATEX II 2G EEx d ia [ia] IIC T6 |
|
|
FM | Class I, II, III |
| Div 1/2, groups |
|
|
06/2009 - SFIDK.PS.050.F2.02 A5E02100423 | www.siemens.com/flow | 69 |