INSTALLATION 3

 

SITRANS FX300

 

 

 

3.6.2 Installing devices in flange design

Figure 3-12: Installing devices in flange design

1Gasket

2Bolts with fixing nuts

• Use bolts and fastening nuts 2 to attach the measuring device to one side of the flange.

While doing so, insert the gaskets 1 between measuring sensor and flange and align them.

Check that the gasket is concentric and that it is not protruding into the pipe cross-section.

Install the gasket, bolts and fastening nuts on the other side of the flange.

Align the measuring device and the gaskets so they are concentric.

Now tighten all nuts bit by bit alternately across the diagonal.

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

29

Page 29
Image 29
Siemens FX300 manual Installing devices in flange design