Siemens FX300 manual Device description, Free air delivery measurement FAD optional

Models: FX300

1 80
Download 80 pages 7.94 Kb
Page 13
Image 13

 

 

DEVICE DESCRIPTION 2

 

SITRANS FX300

 

 

 

2.2.3 Device description

Figure 2-4: Device description

1Signal converter

2Cable feedthrough grey, standard version

3Pressure sensor, optional

4Shut-off valve, optional

5Measuring sensor

6Centering ring

2.2.4Free air delivery measurement - FAD (optional)

A (air) compressor draws air from the ambient atmosphere, compresses it and delivers it at the required pressure. Since the ambient atmosphere also contains water vapour, what the compressor draws in is a mixture of air and water vapour. Free air delivery measurement is to be understood under this condition. Most manufacturers specify free air delivery only at standard intake conditions. What the user ultimately requires as process air must first be determined before measuring can take place with an accuracy of ±1%.

The vortex flowmeter with the optional FAD function can measure the free air delivery online, humidity and speed compensated, regardless of its function as standard flowmeter. The integrated software evaluates the free air delivery automatically online.

The menu-driven, user-friendly software prompts the operator to enter the pressure, relative humidity, the required as well as current discharge pressure.

The steam tables and compressibility tables are saved as standard. The measuring device is optionally available with a pressure sensor which measures the discharge pressure online, making manual input of the values unnecessary.

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

13