Siemens FX300 manual Menu item Quick Setup

Models: FX300

1 80
Download 80 pages 7.94 Kb
Page 49
Image 49

 

 

 

 

 

OPERATION 6

 

SITRANS FX300

 

 

 

6.5.4 Menu item Quick Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

Level

Designation

Selection / entry field

Explanation

 

 

 

 

 

 

1.1.1

Language

 

Select menu language

 

 

 

 

 

 

 

German ...

German language

 

 

 

 

 

 

 

 

 

 

 

French

French language

 

 

 

 

 

 

 

 

English ...^

English language

 

 

 

 

 

 

1.1.2

Location

0000000000

Enter the name of the location (max.

 

 

Location......^

10 characters)

 

1.1.3

Maes.Inst

 

Select type of flow measurement

 

 

 

 

 

 

 

Volume

Volume measurement

 

 

 

 

 

 

 

 

 

 

 

Norm. Vol. 1

Standard volume flow measurement

 

 

 

 

 

 

 

 

Mass ...^

Mass flow measurement

 

 

 

 

 

 

1.1.4

Max. Flow

 

Set maximum flow rate

 

 

 

 

 

 

 

 

 

 

 

 

2

m3/h

Select unit for volume flow

 

 

 

Unit ...^

measurement

 

 

 

 

 

 

 

 

 

888888888

 

 

 

 

 

Upp.Limit

 

 

 

 

 

 

 

 

 

 

00600.0000 or other value

Enter value for the maximum volume

 

 

 

m3/h ......^

flow

 

 

 

Display Unit /

Display flow rate in units /

 

 

 

Display %Max Flow ...^

in % of maximum flow rate

 

 

 

 

 

 

 

3

m3/h norm

Select unit for standard volume flow

 

 

 

Unit ...^

measurement

 

 

 

 

 

 

 

 

00600.0000 or other value

Enter value for the maximum

 

 

 

m3/h norm ......^

standard volume flow rate

 

 

 

Display Unit /

Display flow rate in units /

 

 

 

Display %Max Flow ...^

in % of maximum flow rate

 

 

 

 

 

 

 

4

kg/h

Select unit for mass flow

 

 

 

Unit

measurement

 

 

 

 

 

 

 

 

00600.0000 or other value

Enter value for the maximum mass

 

 

 

kg/h ......^

flow rate

 

 

 

Display Unit /

Display flow rate in units /

 

 

 

Display %Max Flow ...^

in % of maximum flow rate

 

 

 

 

 

 

 

1.1.5

Min. Flow

001111111

 

 

 

 

 

 

 

 

 

00300.0000

The minimum flow rate value is

 

 

 

 

 

 

m3/h ^

factory-set.

 

1.1.6

Timeconst.

00002.0000

Enter the time constant for the

 

 

s ......^

measured value output in seconds

 

 

 

 

(0 – 20 s)

 

 

 

 

0: disabled

 

 

 

 

 

 

1only with gas

2available if Maes.Inst = Volume (see menu item 1.1.3)

3available if Maes.Inst = Norm. Vol. (see menu item 1.1.3)

4available if Maes.Inst = Mass (see menu item 1.1.3)

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

49