TECHNICAL DATA 8

 

SITRANS FX300

 

 

 

8.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local representative.

Additional information (certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website .

Measuring system

Application range

Flow measurement of liquids, gases and vapours

 

 

Operating method / measuring

Karman vortex street

principle

 

 

 

Measured value

 

 

 

Primary measured value

Number of separated vortices

 

 

Secondary measured value

Operating and standard volumetric flow, mass flow

 

 

Signal converter

 

 

 

Versions

Compact

 

 

 

Option: Ex version

 

 

Measuring sensor

 

 

 

Standard

Basic device in flange version (with integrated temperature

 

measurement)

 

 

 

Basic device in sandwich version (with integrated temperature

 

measurement)

 

 

Optional

Basic device with additional pressure measurement

 

 

 

Basic device with additional pressure measurement and shut-off

 

valve for pressure sensor

 

 

 

Dual measuring device in both flange and sandwich version

 

(redundant measurement)

 

 

 

Dual measuring device in flange version with additional pressure

 

measurement

 

 

Display and user interface

 

 

 

Local display

2 lines, 10 characters per line

 

 

Operating and display languages

German, English, French

 

 

Measuring accuracy

Reference condition

Water at 20ºC

 

 

 

Air at 20°C and 1.013 bar abs.

 

 

Accuracy

Based on volume flow

 

 

Liquids

±0.75% of measured value (Re 20000)

 

 

 

±2.0% of measured value (10000 < Re < 20000)

 

 

Gases and steams

±1.0% of measured value (Re 20000)

 

 

 

±2.0% of measured value (10000 < Re < 20000)

 

 

 

Pressure and temperature compensation: ±20000% of measured

 

value (Re 20000); ±10000% of measured value (20000 < Re < 20000)

Repeatability

±0.1% of measured value

 

 

Long-term stability

±0.01% of measured value

 

 

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow