SERVICE 7

 

SITRANS FX300

 

 

 

7.1 Replacing signal converter / LCD display

The signal converter has to be replaced by a converter of the same type. The following parameters have to be observed for it:

The item number must match: 2.143670.xxx

The software version 2 must match.

The basic version has no software identification

The gas version is marked: "gas"

The steam version is marked: "steam"

Figure 7-1: Board, example

1Connector for display

2Version number, software identification

3Connector for measuring sensor

4Spacer pins

5Fixing screw (Phillips)

The following steps are to be performed:

Switch off the power supply.

Unscrew the front cover.

Detach the display from the spacer pins.

Detach the display cable 1.

Detach the measuring sensor cable 3.

Loosen the three fixing screws 5 (Phillips).

Pull out signal converter.

Insert new signal converter.

Tighten the three screws.

Attach measuring sensor cable 3 (Caution: ensure that the measuring sensor cables are not on top of the spacer pins 4 May be damaged).

Attach display cable 1.

Attach display in desired position, apply even pressure to the entire surface.

Screw on cover by hand.

06/2009 - SFIDK.PS.050.F2.02 A5E02100423

www.siemens.com/flow

63

Page 63
Image 63
Siemens FX300 manual Replacing signal converter / LCD display, Following steps are to be performed