3.4.2

Medium

 

 

 

Set process medium

 

 

 

(available if Fluid = Gas /

 

 

 

 

 

 

 

Air ...

 

Air

 

 

 

Wet Gas, see menu item

 

 

 

3.4.1)

 

Ammonia ...

Ammonia ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Argon ...

 

Argon

 

 

 

 

 

 

 

 

 

 

 

 

etc.

...^

other gases not listed here

 

 

 

 

 

 

 

 

 

3.4.3

% Gas

 

 

 

Determine composition of gas mixture

 

 

 

(available if Fluid = Gas

 

 

 

 

 

 

 

050.000000

 

Select gas and enter percentage

 

 

 

Mix., see menu item 3.4.1)

 

 

 

Air ......^

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100.00

 

Total percentage

 

 

 

 

 

Total % ^

 

 

 

 

 

 

 

 

 

 

3.4.4

%Rel.Hum .

0000000.00

...

Determine relative humidity

 

 

 

(available if Fluid = Wet

% Rel.Hum

 

 

 

 

Gas, see menu item 3.4.1)

...^

 

 

 

 

 

 

 

 

 

 

 

3.4.6

FAD Unit.

 

 

 

Determine unit for FAD

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

FAD m3/h

 

Set unit for FAD

 

 

 

FAD meter, see menu

 

 

 

item 5.4.1, service

Unit

...^

 

 

 

 

personnel only)

 

 

 

 

 

 

 

Disp. on /

 

Display measured value /

 

 

 

 

 

 

 

 

 

 

Disp. off ...^

Do not display measured value

 

 

 

 

 

 

 

 

3.4.7

Suct.Temp.

 

 

 

Enter temperature in suction area of compressor

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

°C

 

 

Select temperature unit

 

 

 

FAD meter, see menu

...^

 

 

 

item 5.4.1, service

Unit

 

 

 

 

 

personnel only)

0000200.00

 

Enter temperature value

 

 

 

 

 

°C ......^

 

 

 

3.4.8

Atm.Press.

 

 

 

Atmospheric pressure

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

Pa

 

 

Select pressure unit

 

 

 

FAD meter, see menu

...^

 

 

Unit

 

 

 

 

item 5.4.1, service

 

 

 

 

personnel only)

00001.0000

 

Enter pressure value

 

 

 

 

 

Pa ......^

 

 

 

3.4.9

Fil. P. Drop.

 

 

 

Pressure drop via filter at compressor inlet

 

 

 

(available if Meter Type =

 

 

 

 

 

 

 

Pa

 

 

Select pressure unit

 

 

 

FAD meter, see menu

 

 

 

 

Unit ...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

personnel only)

00000.0000

 

Enter pressure value

 

 

 

 

 

Pa ......^

 

 

 

3.4.10

Inlet RH

0000060.00

...

Enter relative humidity in suction area of compressor

 

 

 

(available if Meter Type =

% Rel.Hum

 

 

 

 

FAD meter, see menu

...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.11

Actual Rpm

0001500.00

 

Current speed of compressor motor in revolutions per

 

 

 

(available if Meter Type =

RPM ^

 

minute

 

 

FAD meter, see menu

 

 

 

 

 

 

 

item 5.3.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.12

Rated Rpm.

0001500.00

 

Rated speed of compressor motor in revolutions per

 

 

 

(available if Meter Type =

RPM ^

 

minute

 

 

FAD meter, see menu

 

 

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

3.4.13

Outlet RH

0000100.00

...

Enter relative humidity at measuring device

 

 

 

(available if Meter Type =

% Rel.Hum

(compressor outlet)

 

 

FAD meter, see menu

...^

 

 

 

 

 

item 5.4.1, service

 

 

 

 

 

 

 

personnel only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 