6 OPERATION |
|
|
SITRANS FX300 |
| |
|
|
|
6.3 Overview of the most important functions and units
INFORMATION!
A complete list of all functions and short descriptions is provided in the appendix. All default parameters and settings are adapted for the specific customer.
Level | Designation | Explanation |
|
|
|
1.1.1 | Language | Select the menu language |
|
|
|
1.1.4 | Max. Flow | Maximum flow rate |
|
| The value set is represented by a 20 mA analogue current output. If the current |
|
| value exceeds the preset value, an alarm is indicated. |
1.1.5 | Min. Flow | Minimum flow rate |
|
| The set value does not represent the 4 mA value of the current output. |
1.1.6 | Timeconst. | Time constant, damping value [s] |
|
|
|
2.1.1 | Test I | Check current output |
|
|
|
2.1.2 | Test P | Test pulse output |
|
|
|
3.1.1 | Error Msg. | Error indicator |
|
| Yes: error messages are displayed |
|
| No: error messages are suppressed. A flashing cursor at the top left indicates |
|
| that error messages are present. |
|
|
|
Table
Volume mass units
Volume |
| Standard volume | Mass | ||
|
|
|
| ||
Liquids, steams, gases | Air | Gas | Liquids, steams, gases | ||
|
|
|
| ||
m3/h | FAD m3/h | m3/h (norm) | kg/h | ||
m3/min | FAD m3/min | m3/min (norm) | kg/min | ||
m3/s | FAD m3/s | m3/s (norm) | kg/s | ||
t/h | |||||
L/h | FAD L/h | L/h (norm) | t/min | ||
L/min | FAD L/min | L/min (norm) | t/s | ||
L/s | FAD L/s | L/s (norm) | lb/h | ||
ft3/h | FAD ft3/h | ft3/d (std.) | lb/min | ||
3 | /min | 3 | 3 | lb/s | |
ft | FAD ft /min | ft /h (std.) | g/min | ||
ft3/s | FAD ft3/s | ft3/min (std.) | |||
g/s | |||||
gal/h | User Def. | ft3/s (std.) | |||
User Def. | |||||
gal/min |
| User Def. |
| ||
gal/s |
|
|
| ||
ImpGal/h |
|
|
| ||
ImpGal/min |
|
|
| ||
ImpGal/s |
|
|
| ||
cm3/h |
|
|
| ||
cm3/min |
|
|
| ||
cm3/s |
|
|
| ||
dm3/h |
|
|
| ||
dm3/s |
|
|
| ||
bbl/h |
|
|
| ||
bbl/d |
|
|
| ||
User Def. |
|
|
| ||
|
|
|
|
|
Table
44 | www.siemens.com/flow | 06/2009 - SFIDK.PS.050.F2.02 A5E02100423 |