Johnson Controls TG9S'MP Section Xii Replacement Parts List, Replacement Part Contact Information

Models: GG9S'MP TG9S'MP

1 40
Download 40 pages 49.32 Kb
Page 38
Image 38
DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

364861-UIM-H-0712

DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

The control in this furnace is equipped with memory that will store up to five error codes to allow a service technician to diagnose problems more easily. This memory will be retained even if power to the furnace is lost. This feature should only be used by a qualified service tech- nician.

If more than five error codes have occurred since the last reset, only the five most recent will be retained. The furnace control board has a but- ton, labeled "LAST ERROR" that is used to retrieve error codes. This function will only work if there are no active thermostat signals. So any call for heating, cooling or continuous fan must be terminated before attempting to retrieve error codes.

SECTION XII: REPLACEMENT PARTS LIST

DESCRIPTION

MOTOR

MOTOR, DIRECT DRIVE BLOWER

BLOWER, COMBUSTION

ELECTRICAL

CAPACITOR, RUN

SWITCH, LIMIT

CONTROL, FURNACE

IGNITER

SENSOR, FLAME

SWITCHES, PRESSURE

SWITCH, DOOR

TRANSFORMER

VALVE, GAS

CONTROL, TEMPERATURE

AIR MOVING

HOUSING, BLOWER

WHEEL, BLOWER

FABRICATED PARTS

RESTRICTOR, COMBUSTION BLOWER

BURNER, MAIN GAS

BRACKET, IGNITER

SHELF, BLOWER

RAIL, BLOWER (2 Req’d)

BRACKET, BLOWER TRACK (2 Req’d)

HEAT EXCHANGER ASS’Y

To retrieve the error codes, push the LAST ERROR button. The LED on the control will then flash the error codes that are in memory, starting with the most recent. There will be a two-second pause between each flash code. After the error codes have all been displayed, the LED will resume the normal slow green flash after a five second pause. To repeat the series of error codes, push the button again.

If there are no error codes in memory, the LED will flash two green flashes. To clear the memory, push the LAST ERROR button and hold it for more than five seconds. The LED will flash three green flashes when the memory has been cleared, then will resume the normal slow green flash after a five-second pause.

DESCRIPTION

FABRICATED PARTS Continued

MANIFOLD, GAS

PAN, BOTTOM

PANEL, TOP

PANEL, DOOR (2 Req’d)

PANEL, BLOCKOFF

MISCELLANEOUS

ORIFICE, BURNER (Natural #45)

SIGHT GLASS, OVAL (2 Req’d)

GASKET, FOAM (Door) (1.5 ft req’d)

PAN, CONDENSATE

BRACKET, DOOR

HARNESS, WIRING

FERRULE (3 Req’d)

GROMMET (3 Req’d)

MOTOR MOUNT

TUBING, SILICON

HOSE, RAIN GUTTER

HOSE, CONDENSATE

PLUG, SEAL, 7/8”

PLUG, SEAL, 2-3/8”

PLUG, VENT PIPE

BAG, PARTS

KNOB, QUARTER TURN (4 Req’d)

DIAGRAM, WIRING

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

Visit our website at www.source1parts.com for the following information:

1.Search for a part or browse the catalog.

2.Find a dealer or distributor.

3.Customer Service contact information.

a.Click on the “Brand Links” button

b.Click on the “Customer Service” buttont

You can contact us by mail. Just send a written request to:

Johnson Controls Unitary Products

Consumer Relations

5005 York Drive

Norman, OK 73069

38

Johnson Controls Unitary Products

Page 38
Image 38
Johnson Controls TG9S'MP Section Xii Replacement Parts List, Replacement Part Contact Information, UIM-H-0712, Electrical

FAQ

How do I retrieve error codes from the control in the furnace?

To retrieve the error codes, push the LAST ERROR button on the control, and the LED will flash the error codes in memory.

What should I do if there are more than five error codes in memory?

If more than five error codes have occurred, only the five most recent will be retained. Push the LAST ERROR button to retrieve the most recent error codes.

Where can I request a complete parts list for Johnson Controls Furnace?

You can request a complete parts list from Johnson Controls Unitary Products by visiting their website or contacting them by mail at the provided address.