Johnson Controls GG9S'MP Section Iii Filters, UIM-H-0712, Filter Installation, Left Side, Front

Models: GG9S'MP TG9S'MP

1 40
Download 40 pages 49.32 Kb
Page 9
Image 9
LEFT SIDE

364861-UIM-H-0712

LEFT SIDE

Combustion Air Inlet

Condensate Drain

Gas Pipe

(Downflow)

Entry

Vent Outlet

Electrical

 

Entry

 

Condensate

 

Drain

 

Thermostat

 

Wiring

28.5”

 

29.5”

 

(For Cladded door add appoximately an additional .75”)

FRONT

A

 

 

RIGHT SIDE

 

 

 

Combustion Air Inlet

 

 

Gas Pipe

Condensate Drain

 

 

Entry

(Downflow)

 

 

Electrical

 

 

 

Entry

Vent Outlet

 

33

Condensate

23”

 

 

Drain

 

 

 

 

 

Thermostat

Optional Return Air

 

 

Wiring

14”

 

Cutout (Either side)

 

 

 

 

 

 

 

 

1”

 

 

1.5”

 

.56”

23.8”

3”

 

 

 

Vent

 

 

Outlet

B

Combustion

 

Air Inlet

 

 

C

 

 

.56”

.56”

 

20”

 

 

 

SUPPLY END

B

24.25”

RETURN END
FIGURE 13: Dimensions

Table 3: Cabinet and Duct Dimensions

BTUH (kW)NominalCabinet

 

Cabinet Dimensions (Inches)

 

Approximate

 

 

Operating Weights

Input

CFM (m3/min)

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

A (in)

A (cm)

B (in)

B (cm)

C (in)

C (cm)

Lbs (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

40 (11.7)

800 (22.7)

A

14 1/2

36.8

13 3/8

34.0

11 3/4

29.8

113 (51.3)

60 (17.6)

1000 (28.3)

A

14 1/2

36.8

13 3/8

34.0

11 3/4

29.8

118 (53.5)

60 (17.6)

1200 (34.0)

B

17 1/2

44.4

16 3/8

41.6

13 1/4

33.7

122 (55.3)

80 (23.4)

1200 (34.0)

B

17 1/2

44.4

16 3/8

41.6

14 3/4

37.5

126 (57.2)

80 (23.4)

1600 (45.3)

C

21

53.3

19 7/8

50.5

16 1/2

41.9

136 (61.7)

80 (23.4)

2200 (62.3)

C

21

53.3

19 7/8

50.5

16 1/2

41.9

139 (63.0)

100 (29.3)

1600 (45.3)

C

21

53.3

19 7/8

50.5

18 1/4

46.4

142 (64.4)

100 (29.3)

2000 (56.6)

C

21

53.3

19 7/8

50.5

18 1/4

46.4

145 (65.8)

120 (35.1)

1600 (45.3)

D

24 1/2

62.2

23 3/8

59.4

21 3/4

55.2

153 (69.4)

120 (35.1)

2000 (56.6)

D

24 1/2

62.2

23 3/8

59.4

21 3/4

55.2

156 (70.7)

130 (38.1)

2000 (56.6)

D

24 1/2

62.2

23 3/8

59.4

No Hole

No Hole

160 (72.5)

SECTION III: FILTERS

FILTER INSTALLATION

All applications require the use of a field installed filter. All filters and mounting provision must be field supplied.

Filters must be installed external to the furnace cabinet. DO NOT

attempt to install filters inside the furnace.

NOTICE

Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter.

Table 4: Recommended Filter Sizes (High Velocity 600 FPM)

CFM (m³/min)

Cabinet Size

Side (in)

Bottom (in)

800 (22.7)

A

16 x 25

14 x 25

1000 (28.3)

A

16 x 25

14 x 25

1200 (34.0)

A

16 x 25

14 x 25

1200 (34.0)

B

16 x 25

16 x 25

1600 (45.3)

B

16 x 25

16 x 25

1600 (45.3)

C

16 x 25

20 x 25

2000 (56.6)

C

(2) 16 x 25

20 x 25

2200 (62.3)

C

(2) 16 x 25

20 x 25

2000 (56.6)

D

(2) 16 x 25

22 x 25

1.Air velocity through throwaway type filters may not exceed 300 feet per min- ute (91.4 m/min). All velocities over this require the use of high velocity fil- ters.

2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one side return with a transition to allow use of a 20x25 filter.

Johnson Controls Unitary Products

9

Page 9
Image 9
Johnson Controls GG9S'MP Section Iii Filters, UIM-H-0712, Filter Installation, Johnson Controls Unitary Products, Front

FAQ

What are the required filter sizes for Johnson Controls Furnace models TG9S'MP and GG9S'MP?

The recommended filter sizes vary based on the CFM and cabinet size. For example, for a CFM of 800, a cabinet size A requires a 16x25 filter on the side and a 14x25 filter at the bottom.

Can filters be installed inside the furnace cabinet?

No, filters must be installed external to the furnace cabinet. Attempting to install filters inside the furnace is not recommended.

What is the maximum air velocity for throwaway type filters?

The maximum air velocity for throwaway type filters is 300 feet per minute (91.4 m/min). High velocity filters are recommended for velocities exceeding this limit.