 Troubleshooting Information
 Troubleshooting Information
| Symptom | Cause | Solution | 
| 
 | 
 | 
 | 
| Power LED off | No power at hub | Check the power cord connections. | 
| 
 | In a stack, no | Check the power cord. In a stack, the | 
| 
 | power at hub but | termination circuitry gets power from the | 
| 
 | Terminator LED is | cascade cable. If one hub in the stack has a | 
| 
 | on | faulty power cord or the cord is unplugged, the | 
| 
 | 
 | Terminator LED remains on and the remaining | 
| 
 | 
 | hubs in the stack operate normally. | 
| 
 | 
 | 
 | 
| Terminator LED of a | Cascade cable not | Check for proper connection. | 
| middle hub in a stack is on | connected properly | 
 | 
| 
 | 
 | 
 | 
| Link LED off or intermittent | Port connection | Check the crimp on the  | 
| 
 | not functioning | make sure that the plug is properly inserted and | 
| 
 | 
 | locked into the port at both the hub and device. | 
| 
 | 
 | Make sure cabling is Category 5 and meets the | 
| 
 | 
 | requirements for 100 Mbps operation. | 
| 
 | 
 | Check installation of the network interface cards | 
| 
 | 
 | and verify that they are 100 Mbps capable. Be | 
| 
 | 
 | sure that the proper software driver is loaded. | 
| 
 | 
 | Check link LEDs on the network adapter card | 
| 
 | 
 | and PC or workstation. Make sure cables and | 
| 
 | 
 | connectors are correct. | 
| 
 | 
 | 
 | 
| Collision LED on or | Collisions taking | Collisions are normal on Ethernet networks. | 
| blinking | place on network | Excessive collisions can be caused by incorrect | 
| 
 | segment(s) | cabling, connectors, or wiring techniques or can | 
| 
 | 
 | occur when the network is too busy. Ensure that | 
| 
 | 
 | the far end is set to  | 
| 
 | 
 | operating properly. Check for these problems. | 
| 
 | 
 | 
 | 
| Problems with port 8 on | Normal/Uplink | Check the Normal/Uplink push button on the | 
| the Model DS508 hub, | push button in the | front panel. | 
| port 16 on the Model | wrong position | 
 | 
| DS516 hub, or port 24 on | 
 | 
 | 
| the Model DS524 hub | 
 | 
 | 
| 
 | 
 | 
 | 
Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide