MRV Communications LX-4000 Series manual Post Test Error Code Sample

Page 53

 

 

Appendix C - POST Test Error Codes

 

 

 

 

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart 6

 

4460

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart 7

 

4470

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart 8

 

4480

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart 9

 

4490

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart A0

 

44A0

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart B0

 

44B0

 

 

 

 

 

 

 

CD1400 Invalid Data Received for Quadart C0

 

44C0

 

 

 

 

 

 

 

Memory Error at (printing address)

 

5010

 

 

 

 

 

 

 

Memory Data Bus Failed

 

5020

 

 

 

 

 

 

 

Memory Address Bus Failed High

 

5030

 

 

 

 

 

 

 

Memory Address Bus Failed Low

 

5040

 

 

 

 

 

 

 

Flash Checksum Error

 

5055

 

 

 

 

 

 

POST Test Error Code Sample

NOTE: This example applies to 8, 16, 32, and 48 port LX units. The 16, 32, and 48 port LX units use only the first eight LEDs when generating error codes.

The following sample illustrates the Port Status LED sequence for Error 2030 (Reading Invalid Value from PLD System Fail Status Register) on the LX-4008. In this example:

1.A POST test failure occurs on an 8-port unit. All LEDs flash eight times, very quickly, then the error code is displayed.

2.You record that LED 3 turns on. Again, all LEDs flash eight times very quickly, then the rest of the error code is displayed.

3.You record that LEDs 3 and 4 turn on. Figure 22 explains how to interpret the sample error code. NOTE: In hexadecimal, 0 indicates the LED is OFF. 1 indicates the LED is ON.

Each group of four LEDs is converted to a hexadecimal value as follows:

0 = 0000

1 = 0001

2 = 0010

3 = 0011

4 = 0100

5 = 0101

6 = 0110

7 = 0111

8 = 1000

9 = 1001

451-0308

MRV Communications, Inc.

www.mrv.com

53

Image 53
Contents Getting Started with the LX-4000 Series MRV Americas Service and SupportCorporate Headquarters MRV America Sales MRV International SalesFCC Notice Licensing Notice Bsmi Notice Vcci Notice451-0308 Table of Contents Appendix C Post Test Error Codes Figures 451-0308 Tables 451-0308 Customer Support PrefaceOther Documentation Conventions Chapter Overview of the LX-4000 SeriesDescription System SpecificationsHardware Installation Chapter Installing the LX-4000 SeriesPackage Contents Unpack and Inspect the UnitFront Panel LEDs LX-4000 Indicators and InterfacesPort Status LEDs Rear Panel LEDsRCV Link Mbps Environmental and Installation ConsiderationsConnecting the Ethernet Interface Connect the Power CableMounting the Unit into a 19-inch or 23-inch Rack Cable ConnectionsConnect Serial Device Cables Connecting Your Management StationConnecting DC Power Modem Port Optional Powering OnResetting the Unit System Login and PasswordsInstalling the LX-4000 Series First Time Quick Configuration Chapter Configuring the LX-4000 Series for the First TimeConfiguring the LX-4000 Unit for the First Time 451-0308 Assigning an IP Address via the Network Completing the First Time ConfigurationAccessing and Configuring the Graphical User Interface GUI Manually Setting the IP Address Via the CLIMRV Communications, Inc 451-0308 Web Configure Mode Menu/Config Mode Web Access ModeLaunching the EZConfig GUI GUI EZ ConfigurationIP Configuration Menu Software UpgradesBooting from Defaults Accessing and Configuring Additional FeaturesAdditional Considerations Autobauding Feature Command Line Interface CLI Tree StructureReinitializing/Powering Off the Unit Additional Considerations for an Internet EnvironmentChapter Alternative Port Capabilities Sensor Temperature/Humidity PortsConnecting the Temperature/Humidity Sensor Async 4-40access sensor Power ManagementConnecting ConnectingPower Strip Management Telco Alarm Inputs Setup and Usage Using LX Ports as Alarm Inputs and Control OutputsTypical Alarm Inputs Connections Control Output Setup and UsageTypical Interface Design for Control Output Signals LX-4000 Series Specifications Description Appendix a Technical SpecificationsLX-4008, LX-4016 Appendix a Technical Specifications Temperature/Humidity Sensor Specifications Description LX-4000 Series Factory Defaults Description Appendix B Factory DefaultsMain Menu Configuration Factory Default Setting Ppciboot Factory Default SettingsError Code Definitions Appendix C Post Test Error Codes451-0308 Post Test Error Code Sample 3 4 5 6 7 Diagnostic Port Connector Port Serial Device ConnectorsAppendix D Cabling the LX-4000 Series Cabling ConsiderationsModular Adapters 10/100 ConnectorOrdering Cables Pin AssignmentsDB-25 Pins Modem Control/Hardware Flow Control Ordering and Installing the Inlet Connector LockConnecting to the Diagnostic Port Port Modular Adapters RJ-45 to DB-25 RJ-45 Wiring ConsiderationsSupports RTS/CTS Adapter Wiring, LX-Series to DCE, with Ring MRV 8-Wire CablingLX Series MX-151-3027Numerics DB-2556, 61 RJ-4561 RJ-45 jacks Index