MRV Communications EM316E3SF manual Configuration, Jumper Settings Factory Default

Page 8

Fiber Driver

EM316E3 & EM316E3SF

Configuration

Jumper Settings: (Factory Default)

 

 

CONFIGURING THE SWITCH (S1)

 

 

 

SWITCH

SETTINGS

RESULTS

 

 

 

MAN/NMS

*ON

Force switches selections (loop back) regardless of NMS command

 

 

OFF

Default setting comes from switches after power up, but maybe change by NMS

 

 

 

commands

SEC/PRI

ON/OFF

Not used in this application. Reserved for the dual-redundant card.

 

 

Setting is irrelevant to the card

LPBK/NORMA

ON

Loop back mode enabled

 

 

OFF

Normal mode enabled

L

 

 

LONG/SHORT

*ON

Cable length is longer than 250 feet

 

 

OFF

Cable length is shorter than 250 feet

 

 

 

 

SW5

ON/OFF

Setting is irrelevant to this card at this time

 

 

 

Note: LONG/SHORT settings shown above are the recommended setup, but can be change to other polarity if better results/performance can be achieved.

Default Setup: MAN/NMS, LONG/SHORT: ON. All other switches: OFF

ONOFF

5 FORCE / AUTO

4LONG/SHORT CX

3LPBK/NORMAL

2SEC/PRI

1MAN/NMS

1 2 3 4 5

ON

5

4

3

2

1

S1

IMPORTANT NOTICE

The jumper settings shown above should be use only on expansion modules that has printed circuit board assembly (PCBA) number: 1226062-007 or later. This number can be found on a white bar coded label located at the bottom side of the expansion module.

P/N: 1226006-001, REV_L

PAGE 8

Image 8
Contents EM316E3SF How many employees work at installation site? Registration CardSerial number What network medium/media does your organization use ?EM316E3SF Fiber Driver EM316E3 & EM316E3SF Introduction Product DescriptionConnectivity FeaturesRequirements for Managed Module Fiber Optic Display Information LED DefinitionTypical Applications Configuration Jumper Settings Factory DefaultTheory of Operation E3 Line Receiver to fiber optic TransmitterSwitch LPBK/NORM is set to OFF Hardware Installation Preparation Follow all Safety RegulationsDetermine the best location for the chassis Unpacking the unitUnit Installation Take out the required amount of blank panelsFiber Driver EM316E3 & EM316E3SF Troubleshooting Technical Specifications International Support Customer SupportAmericas Support Fiber Driver Division of MRV GlossaryOrdering Information Fiber Driver EM316E3 & EM316E3SF