Murphy CDV300R, CDV100F manual Specifications, Power Supply

Page 12

Specifications

Power Supply

Operating voltage:

12V range (link L2-in place) 7-16 VDC

24V range (link L2-cut) 19-30 VDC

Current consumption:

CDV100F: 25mA typical

CDV300R: 50mA, typical (2 LEDs lit)

Inputs

CANbus:

SAE J1939 protocol, Input fitted with 120 Ohm terminating resistor, removable by cutting link L1.

Outputs

Oil pressure gage, coolant temperature gage

Link selectable for Murphy, VDO or Datcon electric gages

Tachometer

Pulsed DC, approximately 121 Hz @ 1500 RPM

General

Overall dimensions (W x H x D)

Case: 2.7x3.8x0.9 inch (68x96x22mm) (allow 2 inches (50mm) depth with connector)

Weight: approximately .18 lbs (80g)

Environmental sealing

IP60

CDV300R: IP65 from front with CDVG gasket (included)

Operating ambient temperature: -40° F to 185° F (-40°C to +85°C)

Storage temperature: -67°F to 221°F (-55°C to 105°C)

Operating Vibration: .02 lbs (10g) (5-2000 Hz)

Operating Shock: .11 lbs (50g) (3-axis)

Section 78

00-02-0618

04-10-07

- 8 -

Image 12
Contents CANdrive Module 00-02-0618 SectionBefore Beginning Installation of this Murphy Product Table of Contents This page Intentionally Left Blank General Information IntroductionStandard Model Options Installation Instructions ConfigurationConfiguration Table Link Function Link OptionsGage Compatibility Tables Electrical Connection Typical ConnectionTerminal Functions Panel Mounting Operation and Maintenance Gage Driver OutputsIndicating LEDs Maintenance Specifications Power SupplySection 00-02-0618 04-10-07