Multi-Tech Systems MT2834BL, MT2834BA manual Listing On-Line Diagnostics L8, Off Hook H

Page 56

Chapter 5 - Command Mode

Listing On-Line Diagnostics L8

The L8 command displays the current on-line CONNECT status of the modem. This display can be printed and used as a modem status report or as diagnostic information (such as when calling Tech Support). To activate this command first type +++AT<CR>(on-line escape command while maintaining command mode), then type ATL8. What then displays on your monitor is your modem's current on-line condition (e.g., Link Type, Line Speed, Serial Speed, Type of Error Correction/Data Compression, Number of past Retrains, etc.).

Off Hook H

You can make the modem hang up (go On Hook). Entering ATH1<RETURN> brings the line Off Hook, just as if you picked up the telephone set. You can hang up by entering ATH0 or ATH (the default is 0 when no number is entered).

Escape Sequences- Entering Command Mode While Still On-Line +++AT<CR>

It is possible to cause the modem to enter Command mode after the modem has gone on-line with a remote modem, without disconnecting the call. This is done by entering an Escape Code. The default Escape Code used by the modem is three plus signs (+++) followed by the letters A and T, up to sixty command characters (most typically “H”, to hang up), and a RETURN. The number of command characters allowed after +++ AT<CR> , is defined by S-Register S34. S-Register S34 defaults to ten command characters.

When this is done, the modem escapes to Command Mode, executes the command (if any), and then remain in Command mode. For example, to hang up the modem at the end of a call, enter

+++ATH and hit RETURN. There is no need to incorporate pauses before and after the plus signs, as done in earlier modems.

BREAK AT<CR>

The modem provides an alternative Escape method, using a Break signal as the Escape Code. The Break signal allows the start-stop DTE (data terminal equipment) to signal the modem without loss of character transparency. With this method, a BREAK signal is used instead of the three plus signs. The BREAK is followed by the letters A and T, up to 60 command characters, and RETURN. When this is done, the modem executes that command, but remains in On-Line mode unless the command was to hang up and/or reset the modem (an H or Z), in which case the modem would be in the Command Mode after executing that command.

Escape Sequence Options - Entering Command Mode While On-Line %E

As mentioned, the default escape sequence setting is for the modem to respond to the +++ escape method. Optional settings are for the modem to respond to the Break method, for the modem to respond to either the +++ or the Break Methods, for the modem to ignore both methods and not escape, for the modem to respond with no "OK" to +++, and for the modem to respond with "OK" to

+++. The %E command is used to select these options, as follows:

%E0

=

Modem Won’t Escape

%E1

=

+++ AT<CR> Method (default)

%E2

=

Break Method

%E3

=

Either +++ or Break Methods

%E4*

=

No "OK" Response to +++

%E5*

=

"OK" Response to +++

*The %E4 and %E5 commands enable or disable an "OK" response, which is required by some software packages during an escape sequence.

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

56

Image 56
Contents User Guide User Guide Record of Revisions Date DescriptionPatents TrademarksContents Registers Index 117Introduction and Description How To Use This Manual IntroductionModem Features 1 MT2834BA/BL Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834BA LED DisplayControls on PC Board Installation and Connection What Is in Your Modem Package? InstallationSafety Warnings Installation ProcedureMultiModemBA Connections Installing PhoneTools, the Data Communications Software Is Your Modem Ready for Use?Software Configuration and Modem Basics Configuring Your Software Configuring Software for Your ModemSoftware Configuration PC Initialization StringsChanging Default Parameters Configuring Software for Your ComputerOther Parameters AT &F S0=0 &F9 &W0 CRSimple Operations Answer/Originate Voice/Data Toggle SwitchModem Basics Manual Dial and Automatic Answer Dialing/On-Line/Answering Manual Dial and Automatic AnswerAutomatic Leased Line Restoral Operation Manual Dial Backup Call TerminationDial Backup and Leased Line Restoral Dial-Up Operation Manual Call OriginationAutomatic Answering Manual AnsweringCall Termination Abort TimerHandshaking Details Command Mode Functional Modes AT Command EditingCommand Mode Summary of AT Commands Functional ModesStore Modem Configure Data Standard AT Result Codes Result CodesMulti-Tech Result Codes Dialing Commands Dialing Action CommandsDial Modifier Commands Voice/Data Dialing $VDPulse or Tone Dial P T Set Pulse Dial Ratios &PReturn to Command Mode After Dial Command Execution Reverse the Mode of Operation RAutomatic Pauses in Dialing Long Space Disconnect YCalling Card Detect Tones $ Quiet Answer @Phone Number Memory Commands Storing Phone Numbers D...NNumber Linking NN Listing Numbers Stored in Memory LModem Reset Z Configuration and Default Storage CommandsLoading Factory Defaults &F Synchronous Transmit Clock Select &X Async/Sync Mode Switching &MUnix Uucp Spoofing $SP Command Response Result Code Commands Echo Command Mode Characters EResult Codes Enable/Disable and No Response Answer Q Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Phone Line Conditioning Commands Enable/Disable Trelis Coded Modulation #TGuard Tones Not Used in BAI/BLI Models &G Bell/V.21 ToneFallback Modes When On-Line #F Enable/Disable Lowspeed Fast Connect $FCCleardown at Disconnect &CD Auto Speed Detect #A7 RS-232C Interface Control Commands Carrier Detect Control &CData Terminal Ready Control &D CTS Control &RDSR/CD Interaction Control &SF Data Set Ready Control &SCTS/RTS Interaction Control &RF Error Correction Commands Normal Mode &E0Auto-Reliable Mode &E1 Reliable Mode &E2Mode Select #L Auto-Reliable Buffering $ARetransmit Count $R Enable/Disable Auto Reliable Fallback Character $FError Correction/300bps $E Xon/Xoff Flow Control &E5 Flow Control CommandsHardware Flow Control &E4 Hewlett-Packard ENQ/ACK Pacing &E9 Xon/Xoff Pass-Through &E7Send Xon/Xoff Characters #X Normal Mode Modem Flow Control On &E11 Terminal/Computer Initiated Pacing &E13Maximum Block Size &BS Parity Selection #PEnq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Modem Baud Rate $MB Speed Conversion CommandsSpeed Conversion $BA Serial Port Baud Rate $SB Immediate Action Commands Listing On-Line Diagnostics L8 Off Hook HExiting Command Mode, Going Back On-Line O Line Probe CommandsForce Answer Mode a Registers Number of Rings Until Modem Answers Rings Which Have OccurredEscape Code Character Return CharacterTime for Carrier Abort Timer Line Feed CharacterBackspace Character Wait Time for Dial ToneS10 Carrier Loss Disconnect Delay Time S13 Remote Configuration Escape CharacterCarrier Detect Response Time S11 Tone Dialing Tone Spacing and DurationS15 Callback Time Delay S19 MT2834BL Only Dial-Back TimerS16 Callback Attempts S17 Changing Break TimeS26 Failed Password Attempts S29 Local Inactivity TimerS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S25 DTR Dropout TimeS30 Inactivity Timer S32 Time Elapse for Escape SequenceS36 Time Between DTR Inactive and Modem Off-Hook S37 Time Between DTR Active and Modem On-HookS48 Program V.34bis Connect Speeds Examples of Reading Values Reading and Assigning S-Register ValuesExamples of Assigning Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Feature Description Callback Security and Remote ConfigurationRemote Configuration Description To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#CBN0xxxxxxxxxxCRCallback Operational Sequence Procedures Remote Configuration Procedures Remote Configuration Operation ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings Dip-Switch Settings MT2834BA PC BoardDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Recording Option Configurations Switch Function Position EffectDIP Switches #15-16 MT2834BL DIP Switches #13-14DIP Switches #15-16 MT2834BA Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsReplacement Parts Technical SupportInternet Sites Country TelephoneAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting None of the LEDs Light When the Modem Is OnModem Does Not Respond to Commands Appendix B TroubleshootingAppendix B Troubleshooting Modem Dials But Cannot Make a Connection Modem Cannot Connect When Answering Modem Disconnects While On-lineFile Transfer Is Slower Than It Should Be Am Losing DataAm Getting Garbage Characters on the Monitor Command Values Description Appendix C AT Command SummaryAppendix C AT Command Summary DsNd Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100$FCn MT2834BL Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 101$MBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 102$SBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 103Dial Tone Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 104Callback Security/Remote Configuration Command Summary Password Command Summary 25bis CommandsDelayed and Forbidden Numbers Appendix D V.25bis Operation25bis Operation Appendix D V.25bis Operation25bis Mode AT Commands 25bis DIP-Switches25bis Set-Up and Initialization Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 10825bis AT Commands Enable/Disable V.25bis Mode $V CommandChange Serial Baud Rate CSP Command 25bis Responses Result CodesDial Phone Number Provided CRN Command Listing Delayed Phone Numbers RLD CommandListing Forbidden Phone Number RLF Command Disregard or Connect to Incoming Calls DIC or CIC CommandITU V.25bis Country Specific Information Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix D V.25bis Operation BelgiumSingapore Appendix E MultiModemBA Cables Appendix E MultiModemBA/BL CablesFCC Part Appendix F Regulatory InformationFCC Part 68 Telecom Canadian Limitations Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115South African Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 116Index Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 11791-116 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 118PBX/CBX Disconnect Drop Time for DSR/CTS/CD63 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119