Multi-Tech Systems MT2834BA, MT2834BL Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP

Page 79

Chapter 8 - Dip-Switch Settings

Switch #3

dB Transmission Levels

(Asynchronous/Synchronous Mode/Leased Line)

DIP-Switch #3 adjusts dB transmission levels required by some phone carriers. Place DIP-Switch #3 in the DOWN position to enable -9 dB transmission. Place DIP-Switch #3 in the UP position to enable -15 dB transmission.

-9dB Transmission

=

Switch #3 DOWN

-15dB Transmission

=

Switch #3 UP

Factory Default Setting

=

DOWN

Switch #4

AS/400 Mode

(Synchronous Mode/Leased Line/Dial-UP)

The modem can function in the IBM AS/400 environment (appearing like an IBM5853 modem). First, DIP-Switch #7 must be placed in the UP position. This establishes an RTS/CTS condition (state typical for an IBM5853 modem in half-duplex mode). Next, place DIP-Switch #4 in the DOWN position. This "spoofs" the modem into operating like an IBM5853 modem in AS/400 applications. DIP-Switch #4 in the UP position disables this function. Note that the modem must be in Command mode to allow AS/400 mode (DIP-Switch #8 DOWN); and in Synchronous mode (DIP-Switch #12 UP).

AS/400 Mode Enabled

=

Switch #4 DOWN

AS/400 Mode Disabled =

Switch #4 UP

Factory Default Setting

=

UP

Switch #4

Unix UUCP Spoofing

(Asynchronous Mode/Leased Line/Dial-Up)

The modem can be configured for use with Unix equipment which employs ACK flow control to monitor data integrity. The modem can do "UUCP spoofing", where the modem is able to generate ACKs at the DTE interface. Data then is transmitted more time-efficiently, because the delay of waiting for data to be received then waiting for the ACK to be returned at the remote end, is eliminated. Placing DIP-Switch #4 in the DOWN position enables UUCP spoofing.

UUCP Spoofing Enabled

=

Switch #4 DOWN

UUCP Spoofing Disabled

=

Switch #4 UP

Factory Default Setting

=

UP

Switch #5

Enable/Disable Auto-Answer - "Ans"

(Asynchronous Mode/Synchronous Mode/Dial-Up)

In some originate-only applications, you may wish to disable the modem’s automatic answering capabilities. This may be true if you have a telephone set attached to a modem and wish to receive voice calls that you yourself would answer instead of the modem. Place DIP-Switch #5 in the UP position to enable Auto-Answer. Place DIP-Switch #5 in the DOWN position to disable Auto-Answer.

Auto-Answer Enabled

=

Switch #5 UP

Auto-Answer Disabled

=

Switch #5 DOWN

(Factory Default Setting

=

UP)

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

79

Image 79
Contents User Guide Trademarks User GuideRecord of Revisions Date Description PatentsContents Index 117 RegistersIntroduction and Description Introduction How To Use This ManualModem Features Fax Features 1 MT2834BA/BL Series FeaturesTechnical Specifications Power MT2834BA LED Display Modem LED IndicatorsControls on PC Board Installation and Connection Installation Procedure What Is in Your Modem Package?Installation Safety WarningsMultiModemBA Connections Is Your Modem Ready for Use? Installing PhoneTools, the Data Communications SoftwareSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem Software ConfigurationAT &F S0=0 &F9 &W0 CR Changing Default ParametersConfiguring Software for Your Computer Other ParametersModem Basics Answer/Originate Voice/Data Toggle SwitchSimple Operations Manual Dial and Automatic Answer Manual Dial and Automatic Answer Dialing/On-Line/AnsweringDial Backup and Leased Line Restoral Manual Dial Backup Call TerminationAutomatic Leased Line Restoral Operation Manual Call Origination Dial-Up OperationManual Answering Automatic AnsweringHandshaking Details Abort TimerCall Termination Command Mode Command Mode AT Command EditingFunctional Modes Functional Modes Summary of AT CommandsStore Modem Configure Data Multi-Tech Result Codes Result CodesStandard AT Result Codes Dialing Action Commands Dialing CommandsSet Pulse Dial Ratios &P Dial Modifier CommandsVoice/Data Dialing $VD Pulse or Tone Dial P TLong Space Disconnect Y Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingQuiet Answer @ Calling Card Detect Tones $Listing Numbers Stored in Memory L Phone Number Memory CommandsStoring Phone Numbers D...N Number Linking NNLoading Factory Defaults &F Configuration and Default Storage CommandsModem Reset Z Unix Uucp Spoofing $SP Async/Sync Mode Switching &MSynchronous Transmit Clock Select &X Result Codes Multi-Tech or Standard AT &Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Enable/Disable and No Response Answer QResult Codes Basic and Extended and Call Progress Selection Bell/V.21 Tone Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Guard Tones Not Used in BAI/BLI Models &GAuto Speed Detect #A Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Cleardown at Disconnect &CDCTS Control &R 7 RS-232C Interface Control CommandsCarrier Detect Control &C Data Terminal Ready Control &DCTS/RTS Interaction Control &RF Data Set Ready Control &SDSR/CD Interaction Control &SF Reliable Mode &E2 Error Correction CommandsNormal Mode &E0 Auto-Reliable Mode &E1Auto-Reliable Buffering $A Mode Select #LError Correction/300bps $E Enable/Disable Auto Reliable Fallback Character $FRetransmit Count $R Hardware Flow Control &E4 Flow Control CommandsXon/Xoff Flow Control &E5 Send Xon/Xoff Characters #X Xon/Xoff Pass-Through &E7Hewlett-Packard ENQ/ACK Pacing &E9 Parity Selection #P Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Maximum Block Size &BSXon/Xoff Pass-Through Commands Normal/Auto-Reliable/Reliable Mode CommandsEnq/Ack Pacing Commands Speed Conversion $BA Speed Conversion CommandsModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Off Hook H Listing On-Line Diagnostics L8Force Answer Mode a Line Probe CommandsExiting Command Mode, Going Back On-Line O Registers Return Character Number of Rings Until Modem AnswersRings Which Have Occurred Escape Code CharacterWait Time for Dial Tone Time for Carrier Abort TimerLine Feed Character Backspace CharacterS11 Tone Dialing Tone Spacing and Duration S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character Carrier Detect Response TimeS17 Changing Break Time S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S16 Callback AttemptsS25 DTR Dropout Time S26 Failed Password AttemptsS29 Local Inactivity Timer S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS37 Time Between DTR Active and Modem On-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S36 Time Between DTR Inactive and Modem Off-HookS48 Program V.34bis Connect Speeds Examples of Assigning Values Reading and Assigning S-Register ValuesExamples of Reading Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Security and Remote Configuration Callback Feature DescriptionTo change your Remote Configuration feature status Remote Configuration DescriptionAT#CBN0xxxxxxxxxxCR To set parity of the password/message promptCallback Operational Sequence Procedures Remote Configuration Operation Procedures Remote Configuration ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings MT2834BA PC Board Dip-Switch SettingsDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Switch Function Position Effect Recording Option ConfigurationsDIP Switches #15-16 MT2834BA DIP Switches #13-14DIP Switches #15-16 MT2834BL Warranty, Service and Tech Support Warranty, Service, and Technical Support Multi-Tech Systems, Inc. Warranty & Repairs PoliciesRepair Procedures for International Distributors Online Warranty RegistrationCountry Telephone Replacement PartsTechnical Support Internet SitesAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Modem Does Not Respond to CommandsAppendix B Troubleshooting Modem Dials But Cannot Make a Connection Am Losing Data Modem Cannot Connect When AnsweringModem Disconnects While On-line File Transfer Is Slower Than It Should BeAm Getting Garbage Characters on the Monitor Appendix C AT Command Summary Appendix C AT Command SummaryCommand Values Description Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100 DsNdMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 101 $FCn MT2834BLMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 102 $MBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 103 $SBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 104 Dial ToneCallback Security/Remote Configuration Command Summary 25bis Commands Password Command SummaryAppendix D V.25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation 25bis OperationMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 108 25bis Mode AT Commands25bis DIP-Switches 25bis Set-Up and Initialization25bis Responses Result Codes 25bis AT CommandsEnable/Disable V.25bis Mode $V Command Change Serial Baud Rate CSP CommandDisregard or Connect to Incoming Calls DIC or CIC Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Listing Forbidden Phone Number RLF CommandITU V.25bis Country Specific Information Singapore Appendix D V.25bis Operation BelgiumMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix E MultiModemBA/BL Cables Appendix E MultiModemBA CablesFCC Part 68 Telecom Appendix F Regulatory InformationFCC Part Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115 Canadian Limitations NoticeMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 116 South African NoticeMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 117 IndexMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 118 91-116Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119 PBX/CBX Disconnect Drop Time for DSR/CTS/CD63