Multi-Tech Systems ISI5634UPCI, ISI9234PCIE Verifying Successful Loading of the Linux Driver

Page 15

ISI Quick Start Guide

Verifying Successful Loading of the Linux Driver

1.To confirm the successful loading of the driver, execute the command "lsmod". The driver "mtsi_upci" should be listed in the list of modules. If the driver is not listed, invoke the "lsmod" command again and watch for errors.

2.Check that the tty devices (with names of the form "ttyMUxy") are listed under the /dev directory. If the tty devices are not listed, invoke the ". /mknod_script" command again (it was previously run as part of the "make install" script in step 7 of the "Building the Linux Driver" procedure) and watch for errors.

3.To confirm that the tty devices function for each modem on the ISI card, execute the utility "minicom" and dial out on each modem.

Un-Installing the Linux ISI Driver

1.Run the "make clean" script. You must run this command from the "mtsi_upci_driver" directory.

The "make clean" script will delete the "resetport" and "mtsi_upci.o" files.

2. Run the "make uninstall" script.

You must run this command from the "mtsi_upci_driver" directory. The "make clean" script will remove the module "mtsi_upci".

3.Execute the "lsmod" command. The "mtsi_upci" module should no longer be listed. If this module is still listed, then invoke the command "rmmod mtsi_upci" and check again to see whether or not the module is listed.

4.Delete serial ports (these are files with names of the form "ttyMUxy"). To do so, go to the "dev" directory.

Enter the command "rm ttyMUZ".

Using the Linux Port Reset Utility

For the serial cards, the port-reset utility allows you to reset ports without rebooting. For the modem cards, the port-reset utility allows you to reset both ports and modems without rebooting.

To reset a serial port, the DTR pin is set to the low logic level for one second. To reset the modem port, the Reset pin is toggled (i.e., its logic state is inverted and then restored).

1.To reset the port (for serial card) or modem (for modem card) run the command "resetport /dev/ttyMUxy"

(where 'x' stands for card number and 'y' for the port number).

2.On the serial cards, the DTR LED will toggle indicating that the reset has occurred and this toggling might be observable on the modem attached to the port (if the modem is equipped for this indication). There is no similar indication of successful reset on the modem cards.

15

Image 15
Contents Intelligent Serial Interface Trademarks Record of Revision Date DescriptionSafety Warnings Page Driver Installation for Windows Server 2008 and Vista Software InstallationSelect Don’t search online Click Close Select Don’t search online Installation of the Communications PortClick Close Installation of the Modem Page MultTech Systems MT9234SMI Linux Driver Installation Overview Installing the ISI Card Driver in LinuxCreating Linux TTY Device Names Building the Linux DriverVerifying Successful Loading of the Linux Driver Using the Linux Port Reset UtilityClick Initial Setup & Country Sel Configuring your Modems for your CountryISI Quick Start Guide Patents
Related manuals
Manual 42 pages 9.61 Kb

ISI9234PCIE, ISI5634UPCI specifications

The Multi-Tech Systems ISI5634UPCI is a cutting-edge communication platform designed for various industrial applications. As a versatile PCI interface device, it delivers reliable and efficient data communication capabilities for a wide range of connected devices. This product exemplifies the innovative spirit of Multi-Tech Systems, a leader in the field of data communication hardware solutions.

One of the standout features of the ISI5634UPCI is its support for multiple communication protocols which allows it to interface seamlessly with diverse systems. It supports USB, Serial communication, and Ethernet, ensuring compatibility with various legacy and modern devices. This multifunctional capability significantly simplifies the deployment of communication systems, reducing the need for multiple disparate interfaces.

The ISI5634UPCI boasts a robust design built to withstand the rigors of industrial environments. Its durable construction ensures reliability in harsh conditions, making it an ideal choice for manufacturing, transportation, and utility applications. The device operates effectively over a wide temperature range, ensuring consistent performance in both hot and cold environments.

A key aspect of the ISI5634UPCI is its high-speed data transfer capabilities. With a data rate of up to 115.2 Kbps, it facilitates quick and efficient communication, which is essential for real-time applications. This feature is particularly beneficial for systems requiring low-latency data transfer such as remote monitoring and control operations.

The ISI5634UPCI also incorporates advanced security features to protect data integrity and ensure secure communication. This includes built-in encryption and authentication mechanisms, providing peace of mind for users requiring secure data transmissions. The device is designed with compliance in mind, adhering to various industry standards which further enhances its credibility.

Another significant characteristic of the ISI5634UPCI is its user-friendly interface, which simplifies installation and configuration. The provided software supports easy integration with existing systems, allowing for quick deployment without extensive training. Additionally, comprehensive documentation and support from Multi-Tech Systems ease any technical challenges users might encounter.

In conclusion, the Multi-Tech Systems ISI5634UPCI stands out as a reliable, robust, and versatile communication interface suitable for a variety of industrial applications. Its combination of multi-protocol support, high-speed data transfer, enhanced security features, and user-friendly design makes it a top choice for organizations looking to enhance their communication capabilities.