N-Tron 300 manual Hazardous Location Installation Requirements

Page 5

Hazardous Location Installation Requirements

1.WARNING! Do not disconnect while circuit is live, unless area is known to be non-hazardous.

2.WARNING! Install only in accordance with Local & National Codes of Authorities Having Jurisdiction.

3.Class I, Div 2 Installations require that power connections must be current limited at the power source with an in-line fuse rated at 0.5A.

4.Class I, Div 2 installations require that all devices connected to this product must be UL approved for the area in which it is installed.

5.Only UL approved wiring with temperature ratings greater than 90° C permitted for Class I, Div 2 installations operating at temperatures up to70° C ambient.

6.Limited Operating Voltage: 12-30V for Class I, Div 2 installations.

12/29/2005

5

Image 5
Contents Installation Guide Where XX = ST or SC and YY = -15, -40, or 12/29/2005 Laser Safety FXE Products Only Electrical SafetyHazardous Location Installation Requirements Key Features Series Industrial Ethernet SwitchesUnpacking Package ContentsInstallation 300-PM900-PM 900-RM DIN-Rail MountingLED LNKACT Connecting the Unit Applying Power Top ViewSupport FCC Statement TroubleshootingEmissions and Safety Approvals Recommended Minimum Wiring ClearanceTron Limited Warranty