3.2 Configuring Operating Mode

The RAA100 operates in one of two modes: 1) NMEA 2000® Mode, or 2) NMEA 2000® / Analog Gauge Mode. You configure or place the RAA100 into NMEA 2000® Mode when you are connecting the RAA100 directly to the resistive rudder angle sender (see Figure 2) and you are not using an analog gauge. In NMEA 2000® Mode, the RAA100 supplies an electrical current to the resistive rudder angle sender and monitors the changing voltage as the rudder is placed in full port, center, and full starboard positions. Whenever the RAA100 is used together with an analog gauge, then you configure or place the RAA100 into NMEA 2000® / Analog Gauge Mode. In this mode, the analog gauge supplies the electrical current to the resistive rudder angle sender while the RAA100 monitors the changing voltage. Placing the RAA100 into NMEA 2000® / Analog Gauge Mode requires you to configure or program the RAA100 with the analog gauge’s resistance, which is described in Section 3.2.1. You can configure or program a RAA100 operating mode through a display product such as the Maretron DSM200. Refer to the user’s manual for configuring the RAA100 as the manual provides detailed instruction on configuration procedures.

3.2.1 Configuring Analog Gauge Resistance

If you are using the RAA100 in the NMEA 2000® / Analog Gauge Mode, then two different analog gauge resistances need to be measured and programmed into the RAA100. You will need an ohmmeter to make the two resistive measurements, which are 1) the power terminal to sensor terminal resistance measurement (see Section 3.2.1.1), and 2) the ground terminal to sensor terminal resistance measurement (see Section 3.2.1.2). Once you have made these measurements, you can enter the RAA100 gauge resistances through a display product such as the Maretron DSM200. Refer to the user’s manual for configuring the RAA100 as the manual provides detailed instruction on configuration procedures.

3.2.1.1 Power Terminal to Sensor Terminal Resistance Measurement

The first resistance measurement is between the power terminal and the sensor terminal found on the back of the gauge. Before making the measurement, disconnect the power, ground, and sensor wires from the gauge. Then, measure and record the resistance between the power terminal and the sensor terminal (see Section 2.3.1.1 for help in determining which terminal is which). Make sure to adjust the ohmmeter scale to give you whole numbers without over ranging (sometimes indicated by blinking display or a 1 in the far left hand digit position). If you see only numbers right of the decimal point, keep adjusting the scale down (usually the highest ohm scale is indicated by a capital M for mega-ohms or 106 ohms while the next lower scale is indicated with a capital K for kilo-ohms or 103 ohms). Typical resistance values between the power terminal and the sensor terminal are between 100 and 200 ohms so you should be able to use the 200-ohm scale.

3.2.1.2 Ground Terminal to Sensor Terminal Resistance Measurement

The second resistance measurement is between the ground terminal and the sensor terminal found on the back of the gauge. Before making the measurement, disconnect the power, ground, and sensor wires from the gauge. Then, measure and record the resistance between the ground terminal and the sensor terminal (see Section 2.3.1.1 for help in determining which terminal is which). Typical resistance values between the ground terminal and the sensor

Revision 1.0

Page 7

Image 11
Contents RAA100 Rudder Angle Adapter Revision Description Revision HistoryTable of Contents Table of Appendices Table of FiguresList of Tables Introduction FeaturesQuick Install GeneralChoosing a Mounting Location InstallationMounting Location When Used With Analog Gauges Unpacking the BoxMounting Location When Used with Analog Gauge Mounting Location When Used Without Analog GaugesMounting Location When Used Without Analog Gauge Connecting the RAA100Connecting Attached Gray Cable to Rudder Angle Sender Connecting to Nmea 2000 InterfaceConnecting Attached Gray Cable to Analog Gauge Configuring Rudder Instance Number Configuring the RAA100Ground Terminal to Sensor Terminal Resistance Measurement Configuring Operating ModeConfiguring Analog Gauge Resistance Power Terminal to Sensor Terminal Resistance MeasurementCustom Calibration MaintenanceStandard Sender Selection or Custom Calibration Standard Sender SelectionTroubleshooting Procedure TroubleshootingSymptom Electrical Technical SpecificationsSpecifications CertificationsEnvironmental Technical SupportWarranty Return Procedure Maretron 2 Year Limited WarrantyRAA100 Nmea 2000 Periodic Data Transmitted PGNs Appendix a Nmea 2000 Interfacing