RAA100 User’s Manual
Figure 5 – Troubleshooting Guide
If these steps do not solve your problem, please contact Maretron Technical Support (refer to Section 7 for contact information).
6 Technical Specifications
Specifications
Parameter | Value | Comment |
Accuracy | Does Not Include Inaccuracies of Analog Gauge or Sender | |
Resolution | Worst Case (Resolution Better at High Resistance Values) | |
American Standard Senders | Standard Sender Types are User Selectable | |
European Standard Senders | Standard Sender Types are User Selectable | |
Calibration Resistance Range | ||
Electronic Calibration | Yes | Eliminates need to mechanically adjust or calibrate |
Analog Gauge Support | Yes | Can be Used With or Without Analog Gauges |
Certifications
Parameter
NMEA 2000
Maritime Navigation and Radiocommunication Equipment & Systems
FCC and CE Mark
Comment
Level B+
Tested to IEC 60945
Electromagnetic Compatibility
NMEA 2000® Parameter Group Numbers (PGNs) - See Appendix A for Details
Description | PGN # | PGN Name | Default Rate |
Periodic Data PGNs | 127545 | Rudder | 10 Times/Second |
Response to Requested PGNs | 126464 | PGN List (Transmit and Receive) | N/A |
| 126996 | Product Information | N/A |
| 126998 | Configuration Information | N/A |
Protocol PGNs | 059392 | ISO Acknowledge | N/A |
| 059904 | ISO Request | N/A |
| 060928 | ISO Address Claim | N/A |
| 065240 | ISO Address Command | N/A |
| 126206 | NMEA | N/A |
Electrical
Parameter | Value |
Operating Voltage | 9 to 16 Volts |
Power Consumption | <100mA |
Load Equivalence Number (LEN) | 2 |
Reverse Battery Protection | Yes |
Load Dump Protection | Yes |
Comment
DC Voltage
Average Current Drain
NMEA 2000® Spec. (1LEN = 50mA) Indefinitely
Energy Rated per SAE J1113
Mechanical
Parameter | Value |
Size | 3.9”” x 1.2” x 1.0” |
Weight | 9 oz. |
Mounting | Any Orientation |
Comment
Excluding NMEA 2000® Connector & Cable
Page 10 | Revision 1.0 |