LevelOne FSW-1611TX manual Troubleshooting

Page 16

E. Troubleshooting

I.Link LED does not lit after cable is connected to the port.

ØVerify that the other end of the cable is connected to a device that is powered on and on-line.

ØFor TP cable connection to another Switch or Hub, verify that only one end of the cable is connected to a “Crossover” port.

II.100BASE-TX port Link LED is lit, Collision LED is blinking, but traffic is irregular.

ØCheck that the attached device is not set to dedicated Full-Duplex. (Some devices use a physical or software switch to change Duplex modes. Auto-Negotiation may not recognize this type of Full-Duplex setting).

16

Image 16
Contents 16Port 10/100Mbps 13 Fast Ethernet Switch Users GuideFCC Warning Table of Contents Unpacking Information Product Introduction Switching TechnologyFast Ethernet Technology Features Page Front Panel CablingStatus LEDs Rear PanelPage To Locate the Switch on a Desktop InstallationTo stack your Switch Page Helpful Suggestions Prior to InstallationHalf- and Full-Duplex Auto-Negotiation HoweverMAC Address Table Sample ApplicationTroubleshooting Always Check That Product Specifications LED Indicators