IMC Networks McPC 100 Mbps operation manual FX LinkLoss Fxll, TX LinkLoss Txll, FiberAlert FA

Page 7

The McPC 100Mbps also sends out link pulses from its copper and fiber transmitters, but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end. The combination of FiberAlert and LinkLoss allows this information to be obtained, even when physical access to a remote device (and its link integrity LED) is not available.

FX LinkLoss (FXLL)

FX LinkLoss is a troubleshooting feature. When a fault occurs on the fiber segment of a conversation, FX LinkLoss detects the fault and passes this information to the twisted pair segment. If a media converter is not receiving a fiber link, FX LinkLoss disables the transmitter on the media converter’s twisted pair port. This results in a loss of link on the device connected to the twisted pair port.

TX LinkLoss (TXLL)

TX LinkLoss is a troubleshooting feature. When a fault occurs on the twisted pair segment of a conversion, TX LinkLoss detects the fault and passes this information to the fiber segment. If a media converter is not receiving a twisted pair link, TX LinkLoss disables the transmitter on the media converter's fiber port. The result is in a loss of the link on the device connected to the fiber port.

FiberAlert (FA)

FiberAlert minimizes the problems associated with the loss of one strand of fiber. If a strand is unavailable, the IMC Networks device at the receiver end notes the loss of link. The device will then stop transmitting data and the link signal until a signal or link pulse

is received. The result is that the link LED on BOTH sides of the fiber connection will go out indicating a fault somewhere in the fiber loop. Using FiberAlert, a local site administrator is notified of a fault and can quickly determine where a cable fault is located.

WARNING

Enable FiberAlert on one side of a media conversion only. Enabling it on both sides would keep both transmitters off indefinitely.

4

Image 7
Contents McPC 100Mbps PCI Version FCC Radio Frequency Interference Statement WarrantyTable of Contents Configuring the McPC 100Mbps Installing the McPC 100MbpsAbout the McPC 100Mbps AutoCross Jumper SettingsAuto Negotiation on McPC 100Mbps Link Integrity LED IndicatorsEnabling Auto Negotiation LinkLoss and FiberAlertTX LinkLoss Txll FX LinkLoss FxllFiberAlert FA Enabling TX and FX LinkLoss Using FiberAlert and LinkLossEnabling FiberAlert Specifications Installation TroubleshootingIMC Networks Technical Support Electrostatic Discharge Precautions Fiber Optic Cleaning GuidelinesSafety Certifications Document Number 55-80734-00 A1