Installation Troubleshooting

ƒDuring installation, first test the fiber and twisted pair connections with FiberAlert disabled. Then enable FiberAlert, if desired, just before final installation. This will reduce the feature’s interference with testing.

ƒTo test McPC 100Mbps by itself, use the appropriate fiber patch cable. First, connect McPC 100Mbps to the twisted pair device with a twisted pair cable. Next, look a single strand of fiber from the transmit port to the receive port of the media converter. Finally, verify that there are both twisted pair and fiber link on the media converter.

Specifications

Environmental

Operating Temperature

32° - 104° F (0° - 40° C)

Storage Temperature

21° - 160° F (-6° - 71° C)

Humidity:

5 - 95% (non-condensing)

Electrical

Input Load

100/240V±10% ~ 50/60Hz, 0.1/0.05A

Dimensions

A single PCI slot module for use in a PC chassis.

IMC Networks Technical Support

Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);

+32-16-550880 (Europe)

Fax: (949) 465-3020

E-Mail:techsupport@imcnetworks.com

Web: www.imcnetworks.com

6

Image 9
Contents McPC 100Mbps PCI Version FCC Radio Frequency Interference Statement WarrantyTable of Contents Installing the McPC 100Mbps Configuring the McPC 100MbpsAbout the McPC 100Mbps Jumper Settings AutoCrossAuto Negotiation on McPC 100Mbps Enabling Auto Negotiation LED IndicatorsLinkLoss and FiberAlert Link IntegrityFX LinkLoss Fxll TX LinkLoss TxllFiberAlert FA Using FiberAlert and LinkLoss Enabling TX and FX LinkLossEnabling FiberAlert Installation Troubleshooting SpecificationsIMC Networks Technical Support Electrostatic Discharge Precautions Fiber Optic Cleaning GuidelinesSafety Certifications Document Number 55-80734-00 A1