IMC Networks McPC 100 Mbps Enabling TX and FX LinkLoss, Using FiberAlert and LinkLoss

Page 8

Enabling TX and FX LinkLoss

In order to enable the LinkLoss features, remove the cover from the unit and place the jumpers accordingly. Follow the instructions below, referencing the diagram.

1.Make sure that there is no power going to the unit by UNPLUGGING THE POWER CORD.

2.Using a Philllips screwdriver, remove the screws on the corners of the cover.

3.Remove the cover and find the three-pin jumper blocks for TX and FX LinkLoss. Adjust the shunts on the jumpers accordingly.

4.Replace the cover and tighten the screw to secure the cover.

Refer to the following diagrams and table for jumper location and settings.

Using FiberAlert and LinkLoss

The following table provides an overview of the troubleshooting features, their functionality and the recommended settings for a pair of media converters in a typical central/main site to remote site application:

LinkLoss/FiberALert Compared

Feature

Fault Location

Disabled LEDs

Enable At:

FX LinkLoss

Fiber

Twisted Pair

Main Site Only

TX LinkLoss

Twisted Pair

Fiber

Remote Site Only

FiberAlert

Fiber

Fiber

Remote Site Only

This will ensure that any faults, no matter where they occur, can be detected by a administrator located at the central site.

Enabling FiberAlert

Configure FiberAlert on McPC 100Mbps by adjusting a two-position switch, labeled FA, on the faceplate next to the fiber connectors. Enable this feature by moving the switch to the up ON position. Disable by moving the switch to the down OFF position (default).

5

Image 8
Contents McPC 100Mbps PCI Version Warranty FCC Radio Frequency Interference StatementTable of Contents About the McPC 100Mbps Installing the McPC 100MbpsConfiguring the McPC 100Mbps Auto Negotiation on McPC 100Mbps Jumper SettingsAutoCross LED Indicators Enabling Auto NegotiationLinkLoss and FiberAlert Link IntegrityFiberAlert FA FX LinkLoss FxllTX LinkLoss Txll Enabling FiberAlert Using FiberAlert and LinkLossEnabling TX and FX LinkLoss IMC Networks Technical Support Installation TroubleshootingSpecifications Fiber Optic Cleaning Guidelines Electrostatic Discharge PrecautionsSafety Certifications Document Number 55-80734-00 A1