Kathrein 3 manual Model Revision

Page 12

Model Revision 1

Available downstream modules:

-DQM 16: 16 channels, 4 chan. per port

-DS-IO 04: Interface card for downstream module

Note: For each DQM 16 one DS-IO 04 is required.

Available upstream modules:

-DCU 16: 16 channels, 1 chan. per port

-DCU 32: 32 channels, 2 chan. per port

-US-IO 16: Interface card for

upstream modules

Note: For each DCU 16/32 one US-IO 16 is required.

Available module for redundancy operation

-RF-RD: Module for n+1 redundancy in down and upstream, 1+1 redundancy of Switch and Management Module including RF switch and redundancy

software

Note: If the RF-RD module is operated, then a DQM 16 or resp. a DCU 16/32 or resp. SMM-12GE should be foreseen as a redundancy module for each unit.

Note: The required system down and upstream configuration can be factory installed and delivered pre-configured. Modules can also be ordered individu- ally and hot plug and play installed or exchanged during operation.

High operational availability with hot plug-and-play exchangeable modules

Switch and Management Module

-Switch capacity: 48 x 2 Gbps

-12 Ethernet SFP ports 10/100/1000 Mbps

-1+1 redundancy possible using a second module

Note: The number of required SFP modules is determined by the desired data rate and redundancy requirements

Model Revision 2

Available downstream modules:

-DQM 32: 32 channels, 4 chan. per port

-DQM 64: 64 channels, 8 chan. per port

-DS-IO08: Interface card for downstream modules

Note: For each DQM 32/64 one DS-IO08 is required.

Available upstream modules:

-DCU 32: 32 channels, 2 chan. per port

-DCU 64: 64 channels, 4 chan. per port

-US-IO16: Interface card for upstream modules

For each DCU 32/64 one US-IO16 is required.

Available module for redundancy operation

-RF-RD: Module for n+1 redundancy in down and upstream, 1+1 redundancy of Switch and Management module including RF switch and redundancy software

Note: If the RF-RD module is operated, then a DQM 32/64 or resp. a DCU 32/64 or resp. SMM-10xGE should be foreseen as a redundancy module for each unit.

Note: The required system down and upstream configuration can be factory installed and delivered pre-configured. Modules can also be ordered individu- ally and hot plug and play installed or exchanged during operation.

High operational availability with hot plug-and-play exchangeable modules

Switch and Management Module

-Switch capacity: 24 x 20 Gbps

-2 Ethernet 10 GbE SFP+ Ports

-8 Ethernet SFP ports 10/100/1000 Mbps

-1+1 redundancy possible using a second module

Note: The number of required SFP modules is determined by the desired data rate and redundancy requirements

12

Image 12
Contents Docsis 3.0 Cmts Edge QAM S a OverviewFull Docsis 3.0 Features Modular and flexible architectureIntegrated Edge QAM function Extensive ApplicationsGeneral Features Function Overview C2200/ C3200/ C10200Feature Highlights C2200 C2200New C2200 Low Capacity Compact Cmts especially for low capacity requirementsC2200 Special features and functions System Docsis FeaturesAvailable Cmts Configurations C2200 Technical Data Type C2200-xxxx-xxxxC3200 Special Features Function Overview Switch and Management SystemC3200 Module SMMAvailable units and modules C3200 Technical Data TypeC3200-xxxx-xxxx C10200 Carrier Class Cmts For highest requirementsModel Revision C10200 Special Features Function Overview C10200-chassis-DCC10200-DQM 26210420 C10200-DCU-16AC10200-DCU-16S C10200-DCU-32A-R1C10200 Technical Data C10200-xxxx-xxxxC2150 Features Function Overview C2150Separate Edge QAM Operational possibilitiesSnmp C2150 Technical Data C2150-xxxDOCSIS/EuroDOCSIS 3.0 Cable modems DCMWe are always pleased to advise you