ICP DAS USA 8KE4, 8KE8, 8430, 8830 user manual Mounting mechanism, Power supply 20W, Dimension

Page 13

Mounting mechanism

pannel mounting and din-rail mounting

Power supply: 20W

Power requirement: 10 ~ 30 VDC

Power consumption: 3.9 W (for 8KE4)

5.1 W (for 8KE8)

Operating Environment: Operating Temp.: –25°C to +75°C. Storage Temp.: –30°C to +85°C Humidity: 5 ~ 95%,non-condensing

Dimension:

230 x 110 x 75.5 mm (for 8KE4)

354 x 110 x 75.5 mm (for 8KE8)

For more detailed dimensions, please refer to “Appendix A:Dimensions”.

8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10

----- 13

Image 13
Contents I-8430I-8830 I-8KE4-GI-8KE8-G Version 1.0, January8430/8830/8KE4/8KE8 Ethernet I/O Unit User’s Manual 8430/8830/8KE4/8KE8 Table of Contents Download firmware Updating MiniOS7 imageChapter 1. Introduction Ethernet -based Data Acquisition I/O unit 1.1 FeaturesASCII-based protocol DCON Protocol Various SDK provided freeSimultaneous access by a maximum of 6 host PCs I/O configurable via the EthernetUpdateable firmware via the RS-232 port InternetDual Bus design to supports i-8K and i-87K series I/O modules More flexible I/O combination and Compact、fasten、quick to installVentilated housing design to work between -25 ~+75 High performance integrated power supplyBuilt-in Watchdog Input Protection circuitrySRAM 1.2 i-8430/i-8830 Hardware SpecificationsEEPROM Ethernet portDimension Power supply 20WMounting mechanism NVRAM 1.3 i-8KE4/i-8KE8 Hardware SpecificationsReal time clock Dimension 8430 1.4 Front view of 8430/88308830 RS-232/485 COM3Pin assignment of COM1 Port Pin assignment of COM3 Port 8KE4 1.5 Front view of 8KE4/8KE88KE8 Pin assignment of COM1 Port Method b DIN-Rail mounting Frame Ground DIN-Rail Clips 1.6 8430/8830/8KE4/8KE8 installationThe diagrams below show the basic wiring for the Ethernet I/O Step2 Attach power supply 10 ~ 30 VDC22222 1111144444 33333For I-8000 series modules the files are located at 1.7 I/O module installationFor I-87K series modules the files are located at Pin assignment Wire Connection Step2 Connect the wire Step3 Insert the I/O module into the 8KE4/8KE8 2.1 Configure the network settings Chapter 2. Configure the 8430/8830/8KE4/8KE8 and I/O modules2.1.1 By “Configuration Wizard” By “Configuration Wizard“ By “MiniOS7 Utility” By “SMMI Menu”4.1 4.2 4.21 2.1.2 By MiniOS7 UtilityPOWER 2.1.3 By SMMI Menu Network ConfigurationMODE DOWNFollowing is the SMMI menu tree Cursor position Step2 The SMMI menu treeStep3 Selection items that can be changed 2.2 Creating a virtual COM port to map the I/O modules 2.3 Configure I/O modulesDCON Utility 3.1 4.1 4.2 4.3 8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 3.1 The feature of using DCON Protocol Chapter 3. Using the DCON ProtocolStep 2. Send command with cr 3.2 Using the TCP protocol directlyStep 1. Connect to the Ethernet controller Step 3. Receive data from Ethernet controllerThe result will be as below 3.3 Via VxComm technology 4.1 Location of documents and software Chapter 4. Software Development ToolKit freeThe diagram below show the architecture of the SDK DCON Utility DOS 4.2.1 Procedure for using the DCON Utility DOS4.2 DCON Utility DOS DCON Utility DOS version4.3 DCON DLL 4.3.1 Procedure for using the DLLDLL library DCON DLLQuickStartManual.pdf FAQ.pdf4.3.2 VB Example Reading an analog input value Step 7 Write the program code VB Step VB Step VB StepStep 8 Run the project DCON ActiveX 4.4.1 Procedure for using the ActiveX4.4 DCON ActiveX ActiveX ocx component Supported modules4.4.2 VB Example Reading an analog input value InstallOCX.pdfStep 5 Add the ActiveX ocx component to the project Step 7 Write the program code Step 6 Arrange all the components on the formVB Step VB Step VB Step 8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-108430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 4.5 DCON LabVIEW 4.5.1 Procedure for using DCONLabVIEWBundled driver for LabVIEW DCON LabVIEW8000Demo Demo programs for I-8000 I/O modules CallDLLinLabVIEW.pdf Explains how to call a sub-vi of in LabVIEW8000.llb LabVIEW library contains all sub-vi for I-8000 I/O modules DCONDLL.pdf Descriptions of all sub-function in DCONDLLStep3 Select the sub-vi form Functions Palette Select a VI… Step4 Select the target *.lib file LabVIEW library file 4.5.2 LabVIEW Example Reading multi-channel analog Input valueStep5 Select the desired sub-vi Step7 Draw the data flow of sub-vi 4.5.2 LabVIEW Demo Program Reading multi-channel analog input valueStep2 Set the parameters 2.1 2.2Step3 Run the demo 4.6 DCON Indusoft 4.6.1 Procedure for using the Indusoft bundled driver4.6.2 Indusoft Example Reading an analog input value DCON IndusoftStep 4 Run Indusoft and create a new project 5.1 5.2 5.3 5.4Step 5 Include the DCON driver Step 6 Configure the DCON driver Step7 Insert tags to connect to I/O modules 7.1 7.2The address format is Address ModuleID Slot Channel Step8 Arrange all the components on the formStep9 Double click the text box to assign a tag to it 9.1 9.2Step10 Run the project 4.7.1 Introduction 4.7 NAP OPC ServerNAP OPC server OPC Server4.7.2 Procedure for using the OPC server 4.7.3 OPC Server Example Reading an analog input value Step 4 Run the OPC server to search for I/O modules on COM3 4.1 4.2 4.4 4.3Step 5 Save the configuration and close the OPC Server Labview National WIZCON iFix Indusoft CitectStep 6 Run SCADA software to connect to the OPC Server i-8430 Appendix A DimensionsBack View Top ViewBack View i-8830Side View Top Viewi-8KE4 i-8KE8 Basic Command Format Appendix B DCON protocolFrequently used Command table reference B.1 Command Set+2.1234+2.1234 +2.1234 +2.1234 cr #01S3+2.1234+2.1234 +2.1234 +2.1234 Command+2.1234cr #01S3C0#01S3C1-05.000 #01S3C1+09.000$AASi6 A Command to read the dataRead back the Digital Output module value and read the Digital Input module value of a specified slot in the I-8000 unit#01S300AA55cr #01S300428430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 #01S31A00cr #01S31C01#01S31000 Channel StatusSet the Channel 0 DO OFF #01S31001B.2 Hardware interface Use Virtual COM Port interface Appendix C VxComm techniqueThe two application architectures are shown as below Appendix D i-8K and i-87K series I/O modules i-87K series i-8000 seriesAppendix E Updating firmware and MiniOS7 image Power 10~ 30 VDC E.1 Access the controllerCA-0915 Step5 Run MiniOS7 Utility Step6 Select the COM port of the host PC 6.1 6.2i. MiniOS7 image version of the 8430/8830/8KE4/8KE8 2. List files in the Flash ROM 1. MiniOS7 image informationii. Files in the Flash ROM E.2 Updating MiniOS7 image E.3 Download firmware