ICP DAS USA 8830, 8KE8 Description, Command, Channel Status, #01S31000, Set the Channel 0 DO OFF

Page 79
Channel Status

Description

This example is for a single channel. The Digital output Module in slot 3 and channel 10 (0Ah) of the I-8000 unit at address 01h will be set to OFF. This example is only for output modules where the channel number is less than or equal to 16.

The table below show to use command #AASiBjs to set 16-channel digital output module of the specified channel and slot of the I-8000 unit.

Command

Channel Status

Command

Channel Status

#01S31000

Set the Channel 0 DO OFF

#01S31001

Set the Channel 0 DO ON

#01S31100

Set the Channel 1 DO OFF

#01S31101

Set the Channel 1 DO ON

#01S31200

Set the Channel 2 DO OFF

#01S31201

Set the Channel 2 DO ON

#01S31300

Set the Channel 3 DO OFF

#01S31301

Set the Channel 3 DO ON

#01S31400

Set the Channel 4 DO OFF

#01S31401

Set the Channel 4 DO ON

#01S31500

Set the Channel 5 DO OFF

#01S31501

Set the Channel 5 DO ON

#01S31600

Set the Channel 6 DO OFF

#01S31601

Set the Channel 6 DO ON

#01S31700

Set the Channel 7 DO OFF

#01S31701

Set the Channel 7 DO ON

#01S31800

Set the Channel 8 DO OFF

#01S31801

Set the Channel 8 DO ON

#01S31900

Set the Channel 9 DO OFF

#01S31901

Set the Channel 9 DO ON

#01S31A00

Set the Channel 10 DO OFF

#01S31A01

Set the Channel 10 DO ON

#01S31B00

Set the Channel 11 DO OFF

#01S31B01

Set the Channel 11 DO ON

#01S31C00

Set the Channel 12 DO OFF

#01S31C01

Set the Channel 12 DO ON

#01S31D00

Set the Channel 13 DO OFF

#01S31D01

Set the Channel 13 DO ON

#01S31E00

Set the Channel 14 DO OFF

#01S31E01

Set the Channel 14 DO ON

#01S31F00

Set the Channel 15 DO OFF

#01S31F01

Set the Channel 15 DO ON

8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 ----- 79

Image 79
Contents I-8430I-8830 I-8KE4-GI-8KE8-G Version 1.0, January8430/8830/8KE4/8KE8 Ethernet I/O Unit User’s Manual 8430/8830/8KE4/8KE8 Table of Contents Download firmware Updating MiniOS7 imageChapter 1. Introduction Various SDK provided free 1.1 FeaturesEthernet -based Data Acquisition I/O unit ASCII-based protocol DCON ProtocolInternet I/O configurable via the EthernetSimultaneous access by a maximum of 6 host PCs Updateable firmware via the RS-232 portDual Bus design to supports i-8K and i-87K series I/O modules More flexible I/O combination and Compact、fasten、quick to installInput Protection circuitry High performance integrated power supplyVentilated housing design to work between -25 ~+75 Built-in WatchdogEthernet port 1.2 i-8430/i-8830 Hardware SpecificationsSRAM EEPROMDimension Power supply 20WMounting mechanism NVRAM 1.3 i-8KE4/i-8KE8 Hardware SpecificationsReal time clock Dimension RS-232/485 COM3 1.4 Front view of 8430/88308430 8830Pin assignment of COM1 Port Pin assignment of COM3 Port 8KE4 1.5 Front view of 8KE4/8KE88KE8 Pin assignment of COM1 Port Method b DIN-Rail mounting Frame Ground DIN-Rail Clips 1.6 8430/8830/8KE4/8KE8 installationThe diagrams below show the basic wiring for the Ethernet I/O Step2 Attach power supply 10 ~ 30 VDC33333 1111122222 44444For I-8000 series modules the files are located at 1.7 I/O module installationFor I-87K series modules the files are located at Pin assignment Wire Connection Step2 Connect the wire Step3 Insert the I/O module into the 8KE4/8KE8 By “Configuration Wizard“ By “MiniOS7 Utility” By “SMMI Menu” Chapter 2. Configure the 8430/8830/8KE4/8KE8 and I/O modules2.1 Configure the network settings 2.1.1 By “Configuration Wizard”4.1 4.2 4.21 2.1.2 By MiniOS7 UtilityDOWN 2.1.3 By SMMI Menu Network ConfigurationPOWER MODEFollowing is the SMMI menu tree Cursor position Step2 The SMMI menu treeStep3 Selection items that can be changed 2.2 Creating a virtual COM port to map the I/O modules 2.3 Configure I/O modulesDCON Utility 3.1 4.1 4.2 4.3 8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 3.1 The feature of using DCON Protocol Chapter 3. Using the DCON ProtocolStep 3. Receive data from Ethernet controller 3.2 Using the TCP protocol directlyStep 2. Send command with cr Step 1. Connect to the Ethernet controllerThe result will be as below 3.3 Via VxComm technology 4.1 Location of documents and software Chapter 4. Software Development ToolKit freeThe diagram below show the architecture of the SDK DCON Utility DOS version 4.2.1 Procedure for using the DCON Utility DOSDCON Utility DOS 4.2 DCON Utility DOSDCON DLL 4.3.1 Procedure for using the DLL4.3 DCON DLL DLL libraryQuickStartManual.pdf FAQ.pdf4.3.2 VB Example Reading an analog input value Step 7 Write the program code VB Step VB Step VB StepStep 8 Run the project ActiveX ocx component Supported modules 4.4.1 Procedure for using the ActiveXDCON ActiveX 4.4 DCON ActiveX4.4.2 VB Example Reading an analog input value InstallOCX.pdfStep 5 Add the ActiveX ocx component to the project 8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 Step 6 Arrange all the components on the formStep 7 Write the program code VB Step VB Step VB Step8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 DCON LabVIEW 4.5.1 Procedure for using DCONLabVIEW4.5 DCON LabVIEW Bundled driver for LabVIEWDCONDLL.pdf Descriptions of all sub-function in DCONDLL CallDLLinLabVIEW.pdf Explains how to call a sub-vi of in LabVIEW8000Demo Demo programs for I-8000 I/O modules 8000.llb LabVIEW library contains all sub-vi for I-8000 I/O modulesStep3 Select the sub-vi form Functions Palette Select a VI… Step4 Select the target *.lib file LabVIEW library file 4.5.2 LabVIEW Example Reading multi-channel analog Input valueStep5 Select the desired sub-vi Step7 Draw the data flow of sub-vi 4.5.2 LabVIEW Demo Program Reading multi-channel analog input valueStep2 Set the parameters 2.1 2.2Step3 Run the demo DCON Indusoft 4.6.1 Procedure for using the Indusoft bundled driver4.6 DCON Indusoft 4.6.2 Indusoft Example Reading an analog input valueStep 4 Run Indusoft and create a new project 5.1 5.2 5.3 5.4Step 5 Include the DCON driver Step 6 Configure the DCON driver Step8 Arrange all the components on the form 7.1 7.2Step7 Insert tags to connect to I/O modules The address format is Address ModuleID Slot ChannelStep9 Double click the text box to assign a tag to it 9.1 9.2Step10 Run the project OPC Server 4.7 NAP OPC Server4.7.1 Introduction NAP OPC server4.7.2 Procedure for using the OPC server 4.7.3 OPC Server Example Reading an analog input value Step 4 Run the OPC server to search for I/O modules on COM3 4.1 4.2 4.4 4.3Step 5 Save the configuration and close the OPC Server Labview National WIZCON iFix Indusoft CitectStep 6 Run SCADA software to connect to the OPC Server Top View Appendix A Dimensionsi-8430 Back ViewTop View i-8830Back View Side Viewi-8KE4 i-8KE8 Basic Command Format Appendix B DCON protocolFrequently used Command table reference B.1 Command SetCommand #01S3+2.1234+2.1234 +2.1234 +2.1234 cr +2.1234+2.1234 +2.1234 +2.1234+2.1234cr #01S3C0#01S3C1-05.000 #01S3C1+09.000module value of a specified slot in the I-8000 unit A Command to read the data$AASi6 Read back the Digital Output module value and read the Digital Input#01S300AA55cr #01S300428430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 #01S31A00cr #01S31C01#01S31001 Channel Status#01S31000 Set the Channel 0 DO OFFB.2 Hardware interface Use Virtual COM Port interface Appendix C VxComm techniqueThe two application architectures are shown as below Appendix D i-8K and i-87K series I/O modules i-87K series i-8000 seriesAppendix E Updating firmware and MiniOS7 image Power 10~ 30 VDC E.1 Access the controllerCA-0915 Step5 Run MiniOS7 Utility Step6 Select the COM port of the host PC 6.1 6.2i. MiniOS7 image version of the 8430/8830/8KE4/8KE8 2. List files in the Flash ROM 1. MiniOS7 image informationii. Files in the Flash ROM E.2 Updating MiniOS7 image E.3 Download firmware