CS14, CSN14 Series Converter Switches | Installation and User Guide (02/06) |
media-converters etc. Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software, and the result of the auto-negotiation is changed in the managed switch by the manager commands. In such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the CS14 Switches will still work. The auto-cross function cannot be disabled.
When an RJ-45 cable connection is made, and each time LINK is enabled, auto-negotiation takes place (except for legacy products, which do not have auto- negotiation and which go to the default state accordingly). The Magnum Switch advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device at the other end of the cable should similarly advertise / respond. Both sides will agree to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the devices connected, this will result in agreement to operate at either 10 Mbps or 100Mbps speed, and full- or half-duplex mode.
4.3(F- H) Switch, Full-Duplex or Half-Duplex options for Fiber port# 1
The (F–H) manual switch has been provided for fiber port #1, for fixing that
port at Full or Half Duplex as per the requirements. The (F-H) manual switch is being
www . GarrettCom . com