Before installing the equipment, it is necessary to take the following precautions:

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 500C.

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe operation.

3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly the rack system.

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent overloading of the building/s electrical circuits.

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path.

Installation: This section describes installation of the Magnum Mixed-Media 8000X Hub, as well as connection of the various Ethernet media types.

3.1Locating the Magnum 8000X

The location of the Magnum 8000X is dependent on the physical layout of the network and the area to be served. The unit is typically rack mounted in a wiring closet but because it has rubber feet it can also be installed on a shelf or table top. While stacks of up to 3 units and the associated cabling can be accommodated on a shelf or table top, it is recommended that larger stacks be rack mounted. Each unit is shipped with a pair of metal "ears" that attach to each side of the unit to easily accommodate mounting in standard 19" RETMA racks. (Brackets for 23” telco racks are optional at extra cost).

3.2Connecting Ethernet Media

The Magnum 8000X Mixed-Media Fiber Hub is specifically designed to support all standard Ethernet media types within a single hub unit. This is accomplished by using a family of Port Modules (PMs) which can be individually selected and configured per-port. See Section 2.4 for a description of the PMs.

www . GarrettCom . com

21

Image 28
Contents Mixed-Media Fiber Hubs Magnum Mixed-Media Fiber Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPersonal Hubs, 10Mb series Personal Switches , 10/100MbMedia Converters, 10Mb and 100Mb series Introduction Magnum 8000X MIXED-MEDIA Fiber HUB Roubleshooting Revisions Technical Specifications Power Supply, AC InternalNetwork Standards Maximum Ethernet Segment or Domain LengthsDC Power Supply Options Manual SwitchesLED Indicators WarrantySpecifications Switching Port Modules SPMs for bonus port PM Model # Ieee Standard Speed Connector typeMagnum 8000X Mixed-Media Fiber Hubs Switch Port Modules SPMs for the Bonus Port8000X Front Port Modules PMs Magnum 8000X Mixed-Media Fiber Hubs General Information Product DescriptionMagnum 8000X Fiber Hub Chassis A Magnum 8000X, Front ViewC Magnum 8000X Rear Panel View Port Modules PMsSwitch Port Modules SPMs FPM-MSC, FPM-MST, FPM-MV45, FPM-SXMST, & PM-FP5a Inside view of Magnum 8000X with SPM installed. Rear view Filtering and Forwarding / Address LearningSeg Not in table Add source to table Forward Filter None Magnum SPM-FDST Magnum SPM-FDSC Magnum SPM-FDSSCSPM Specification Summary Table Magnum SPM-TTX10 /100 Speed Auto-sensing 8000X front copper ports only Stacking Magnum Mixed-Media 8000X Fiber Hubs7a a stack of one Magnum 8000X and two DS-8016-A’s Internal view of 8000X with bridge module installed Stackable and Scaleable Configurations LEDs for Chassis and PM CardsApplications Magnum 8000X has 16 ports per unit Connecting Ethernet Media Magnum 8000X InstallationLocating the Magnum Connecting Fiber Optic SC-type, Snap-In Connecting Fiber Optic ST-type, twist-lockCopper Connecting Single-Mode Fiber Optic Media Ieee StandardBit Time per Meter BT/m Magnum 8000X Mixed-Media Fiber Hubs PDV = X + 100 + 80 + 80 + 1b Multiple cascaded Magnum 8000X Mixed-Media hubsMax. User Max. Inter Hubs Length mConnections to NICs which support Auto-Negotiation Table-Top or Shelf MountingPreparation for Installing and Removing PMs StopRemove Chassis Cover 1a Removing Chassis CoverConnector socket Installing PM Cards in the MagnumSlot. Align 2b Inserting PM Cards into a Magnum Removing PM CardsPM Cards 10a Removing Chassis Cover Installing an SPM Module in the Magnum 10.1a Top View SPM Module Installed in aPowering the Magnum Removing an SPM Bonus Port ModuleRemove retaining screws for the SPM, face-plate only Remove SPM CardMagnum 8000X Mixed-Media Fiber Hubs Repeater Functionality OperationDual-Speed Functionality 8000X Dual-Speed Hub Functionality Address Learning Address Table MaintenanceThroughput Increase Software Transparency Auto-negotiation and speed-sensingAuto-negotiation per-port for dual-speed hubs occurs when Chassis LEDsPower Budget Calculations for 8000X FPM’s and Fiber Media ’cvrIntroduction Magnum 8000X Port Modules FPM-MST, 100Mbps multi-mode FX-ST-type, twist-lock connector FPM-MSC 100Mbps multi-mode FX-SC-type, snap-in connectorFPM-SSC 100Mbps single-mode FX-SC-type, snap-in connector Activity 2 Link100BASE-FX MT-RJ ConnectorActivity Link FPM-SXMST and Sxmsc 100BASE-SX when available SX short wavelengthPM-RJ45 and RJ45U Twisted Pair PM-FP Must be installedEach empty PM slot Troubleshooting Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationSpecifications for Magnum Mixed -MEDIA 8000X Hubs B3.0 Applications for DC Powered Ethernet HubsB4.0 Installation B4.1 UL RequirementsB5.0 OperationB6.0 Ordering Information B7.0C5.0 Installation C4.0 Features and Benefits of the DUAL-SOURCE DesignC3.0 DUAL-SOURCE OPTION, Theory of Operation C6.0 Ordering Information C5.1 UL RequirementsExample Magnum 8000X-48VDC C7.0

8000X specifications

The GarrettCom 8000X series represents a significant advancement in industrial networking technology, designed specifically for demanding environments that require robust and reliable communication solutions. Known for its versatility and resilience, the 8000X series caters to various industries, including transportation, utilities, and automation, making it a go-to choice for mission-critical applications.

One of the main features of the 8000X is its modular design, allowing users to customize the switch according to their specific networking needs. This feature provides the flexibility to add and remove modules seamlessly, ensuring that the network can adapt as requirements change over time. The modularity also contributes to easier maintenance and upgrades, reducing downtime and enhancing operational efficiency.

The 8000X series is built to operate in harsh environments, with an operating temperature range of -40°C to 85°C, making it suitable for outdoor and industrial applications. Its rugged chassis is designed to withstand vibration and shock, ensuring reliability even in the most challenging conditions.

Equipped with both Ethernet and fiber optic ports, the 8000X series supports a variety of network topologies and facilitates extensive connectivity options. It usually offers multiple gigabit Ethernet ports, allowing for high-speed data transmission. This feature is crucial for applications that demand real-time data processing, such as video surveillance and process control systems.

In terms of security, the GarrettCom 8000X series incorporates advanced features such as VLAN support, access control lists (ACLs), and network monitoring tools. These security measures are essential for protecting sensitive data and maintaining network integrity against potential threats.

The device also supports various network protocols, including IPv4, IPv6, and various industrial protocols such as Modbus. This compatibility ensures that the 8000X can seamlessly integrate into existing infrastructures and communicate effectively with other devices and systems.

Furthermore, the GarrettCom 8000X series is equipped with built-in redundancy features, such as dual power supplies and support for Rapid Spanning Tree Protocol (RSTP), which enhance network reliability and minimize the risk of downtime.

Overall, the GarrettCom 8000X series stands out with its robust construction, modularity, and advanced technology, making it an ideal solution for organizations seeking reliable networking equipment capable of performing under extreme conditions. Its features make it a vital asset for industries focused on maintaining high-performance communication standards.