GarrettCom 8000X manual Pm-Fp, Must be installed, Each empty PM slot

Page 54

Magnum 8000X Mixed-Media Fiber Hubs

 

 

Installation and User Guide (05/ 02)

5.2.8

PM-FP

 

 

 

 

 

The PM-FP is a blank face plate

 

 

Note: The PM-FP

that must be installed in any empty PM slot.

 

 

When the Magnum 8000X chassis contains

 

 

must be installed in

 

 

each empty PM slot.

less than twelve front-mounted PMs, the

 

 

 

 

 

 

 

 

 

 

empty front slots must be covered with the PM-FP face plate PM-FP

in order to maintain proper cooling air flow, and for safety, etc.

www . GarrettCom . com

47

Image 54
Contents Mixed-Media Fiber Hubs Magnum Mixed-Media Fiber Hubs Installation and User Guide TrademarksGarrettCom, Inc Contacting GarrettCom, IncPersonal Switches , 10/100Mb Personal Hubs, 10Mb seriesMedia Converters, 10Mb and 100Mb series Introduction Magnum 8000X MIXED-MEDIA Fiber HUB Roubleshooting Revisions Network Standards Technical SpecificationsPower Supply, AC Internal Maximum Ethernet Segment or Domain LengthsLED Indicators DC Power Supply OptionsManual Switches WarrantySpecifications Switching Port Modules SPMs for bonus port PM Model # Ieee Standard Speed Connector typeSwitch Port Modules SPMs for the Bonus Port Magnum 8000X Mixed-Media Fiber Hubs8000X Front Port Modules PMs Magnum 8000X Mixed-Media Fiber Hubs General Information Product DescriptionMagnum 8000X Fiber Hub Chassis A Magnum 8000X, Front ViewC Magnum 8000X Rear Panel View Port Modules PMsSwitch Port Modules SPMs FPM-MSC, FPM-MST, FPM-MV45, FPM-SXMST, & PM-FP5a Inside view of Magnum 8000X with SPM installed. Rear view Filtering and Forwarding / Address LearningSeg Not in table Add source to table Forward Filter None Magnum SPM-FDST Magnum SPM-FDSC Magnum SPM-FDSSCSPM Specification Summary Table Magnum SPM-TTX10 /100 Speed Auto-sensing 8000X front copper ports only Stacking Magnum Mixed-Media 8000X Fiber Hubs7a a stack of one Magnum 8000X and two DS-8016-A’s Internal view of 8000X with bridge module installed Stackable and Scaleable Configurations LEDs for Chassis and PM CardsApplications Magnum 8000X has 16 ports per unit Magnum 8000X Installation Connecting Ethernet MediaLocating the Magnum Connecting Fiber Optic ST-type, twist-lock Connecting Fiber Optic SC-type, Snap-InCopper Connecting Single-Mode Fiber Optic Media Ieee StandardBit Time per Meter BT/m Magnum 8000X Mixed-Media Fiber Hubs PDV = X + 100 + 80 + 80 + 1b Multiple cascaded Magnum 8000X Mixed-Media hubsConnections to NICs which support Auto-Negotiation Max. User Max. Inter HubsLength m Table-Top or Shelf MountingPreparation for Installing and Removing PMs StopRemove Chassis Cover 1a Removing Chassis CoverInstalling PM Cards in the Magnum Connector socketSlot. Align 2b Inserting PM Cards into a Magnum Removing PM CardsPM Cards 10a Removing Chassis Cover Installing an SPM Module in the Magnum 10.1a Top View SPM Module Installed in aRemove retaining screws for the SPM, face-plate only Powering the MagnumRemoving an SPM Bonus Port Module Remove SPM CardMagnum 8000X Mixed-Media Fiber Hubs Operation Repeater FunctionalityDual-Speed Functionality Address Learning Address Table Maintenance 8000X Dual-Speed Hub FunctionalityThroughput Increase Auto-negotiation per-port for dual-speed hubs occurs when Software TransparencyAuto-negotiation and speed-sensing Chassis LEDsPower Budget Calculations for 8000X FPM’s and Fiber Media ’cvrIntroduction Magnum 8000X Port Modules FPM-MST, 100Mbps multi-mode FX-ST-type, twist-lock connector FPM-MSC 100Mbps multi-mode FX-SC-type, snap-in connectorFPM-SSC 100Mbps single-mode FX-SC-type, snap-in connector Activity 2 LinkConnector 100BASE-FX MT-RJActivity Link FPM-SXMST and Sxmsc 100BASE-SX when available SX short wavelengthPM-RJ45 and RJ45U Twisted Pair Must be installed PM-FPEach empty PM slot Troubleshooting Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationSpecifications for Magnum Mixed -MEDIA 8000X Hubs B3.0 Applications for DC Powered Ethernet HubsB4.0 Installation B4.1 UL RequirementsB6.0 Ordering Information B5.0Operation B7.0C4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 InstallationC3.0 DUAL-SOURCE OPTION, Theory of Operation C5.1 UL Requirements C6.0 Ordering InformationExample Magnum 8000X-48VDC C7.0

8000X specifications

The GarrettCom 8000X series represents a significant advancement in industrial networking technology, designed specifically for demanding environments that require robust and reliable communication solutions. Known for its versatility and resilience, the 8000X series caters to various industries, including transportation, utilities, and automation, making it a go-to choice for mission-critical applications.

One of the main features of the 8000X is its modular design, allowing users to customize the switch according to their specific networking needs. This feature provides the flexibility to add and remove modules seamlessly, ensuring that the network can adapt as requirements change over time. The modularity also contributes to easier maintenance and upgrades, reducing downtime and enhancing operational efficiency.

The 8000X series is built to operate in harsh environments, with an operating temperature range of -40°C to 85°C, making it suitable for outdoor and industrial applications. Its rugged chassis is designed to withstand vibration and shock, ensuring reliability even in the most challenging conditions.

Equipped with both Ethernet and fiber optic ports, the 8000X series supports a variety of network topologies and facilitates extensive connectivity options. It usually offers multiple gigabit Ethernet ports, allowing for high-speed data transmission. This feature is crucial for applications that demand real-time data processing, such as video surveillance and process control systems.

In terms of security, the GarrettCom 8000X series incorporates advanced features such as VLAN support, access control lists (ACLs), and network monitoring tools. These security measures are essential for protecting sensitive data and maintaining network integrity against potential threats.

The device also supports various network protocols, including IPv4, IPv6, and various industrial protocols such as Modbus. This compatibility ensures that the 8000X can seamlessly integrate into existing infrastructures and communicate effectively with other devices and systems.

Furthermore, the GarrettCom 8000X series is equipped with built-in redundancy features, such as dual power supplies and support for Rapid Spanning Tree Protocol (RSTP), which enhance network reliability and minimize the risk of downtime.

Overall, the GarrettCom 8000X series stands out with its robust construction, modularity, and advanced technology, making it an ideal solution for organizations seeking reliable networking equipment capable of performing under extreme conditions. Its features make it a vital asset for industries focused on maintaining high-performance communication standards.