EDID PROGRAMMING

LED

EDID Program Button

 

EDID Recording

Display information (EDID) contains resolution and timing information for your display. This information is needed by the source for proper video output. Follow these steps to record the EDID of the display into the sender unit. If you know that EDID is not required by the source, the followings steps for recording will not be necessary.

1.Power on the display.

2.Insert the included 5V DC power adapter into the sender unit. Using a small pin, press the EDID program button on the sender unit. The LED on the top panel of the unit will blink twice and turn off.

3.Connect the DVI FM500 Extender sender unit to the display using a user/monitor supplied DVI cable.

4.The LED will blink rapidly for approximately 8 seconds while the EDID is being recorded. Once the LED stops blinking and turns off again the monitors EDID will have been successfully recorded.

5.Disconnect the power adapter from the DVI FM500 Extender sender unit, and then disconnect the DVI FM500 Extender sender unit from the display.

6

Image 9
Contents DVI FM500 Extender Rev A4 Technical Support Asking for AssistanceTechnical Support Hours Write ToContents Gefen IntroductionGefen DVI FM500 Extender How It WorksOperation Notes Package Includes FeaturesPanel Layout How to Connect the DVI FM500 Extender Connecting and Operating the DVI FM500 ExtenderLED Edid ProgrammingSpecifications Product Registration WarrantyPage Page Rev A4 Nordhoff St., Chatsworth CA