Finisar FTLX1461E2 manual Eye Safety, VII. DOM Parameters, VIII. Mechanical Characteristics

Page 9

FTLX1461E2 Product Specification – October 2008

Eye Safety

Finisar FTLX1461E2 transponders are Class 1 Laser Products. They are certified per the following standards:

Feature

Agency

Standard

Certificate

 

 

 

Number

Laser Eye

FDA/CDRH

CDRH 21 CFR 1040 and Laser Notice 50

9210176-104

Safety

 

 

 

Laser Eye

TÜV

EN 60825-1: 1994+A11:1996+A2:2001

R 72082131

Safety

 

IEC 60825-1: 1993+A1:1997+A2:2001

 

 

 

IEC 60825-2: 2000, Edition 2

 

Electrical

TÜV

EN 60950

R 72082131

Safety

 

 

 

Electrical

UL/CSA

CLASS 3862.07

1439230

Safety

 

CLASS 3862.87

 

 

 

 

 

Copies of the referenced certificates are available at Finisar Corporation upon request.

VII. DOM Parameters

Parameter

Transponder Temperature Monitor Accuracy1)

Laser Bias Current Monitor Accuracy2)

Transmit Power Monitor Accuracy3)

Receive Power Monitor Accuracy3)

min.

-5

-10

-3

-3

Values typ.

 

Unit

max.

+5

°C

+10

%

+3

dB

+3

dB

1) 0 to 70°C case temperature.

2) 0 to 12.5 mA.

3) -8.2 dBm to +0.5 dBm.

VIII. Mechanical Characteristics

Parameter

Symbol

 

Values

 

Unit

 

 

min.

typ.

max.

 

Module Retention Force (latch strength)

FRET

 

200

 

N

Module Insertion Force

FIN

 

40

 

N

Module Extraction Force (with kick-out)

FEXT-K

 

16

 

N

Module Extraction Force (without kick-out)

FEXT

 

25

 

N

© Finisar Corporation – October 2008

Rev B

Page 9

Image 9
Contents FTLX1461E2 Transmit Functions Receive Functions DC PowerDBm Parameter Symbol Limit Values Unit Min MaxParameter Symbol Values Unit Min Typ Max Electrical DC CharacteristicsXaui I/O DC Characteristics TXLANE0..3 RXLANE0..3 Mdio I/O DC Characteristics MdioXaui Output AC Characteristics RXLANE0..3 Electrical AC CharacteristicsPower-On Reset AC Characteristics Mdio I/O AC Characteristics MdioParameter Symbol Values Unit Min Typ Max Transmitter IV. Optical CharacteristicsStressed Signal Calibration ReceiverPin Connector Fibers and ConnectorsEnvironmental Performance Rail RequirementEye Safety VIII. Mechanical CharacteristicsVII. DOM Parameters Package Outline IX. ReferencesFor More Information