FTLX1461E2 Product Specification – October 2008
Environmental Performance |
|
Operating case temperature: | 0°C to +70°C |
Operating humidity: | 0% |
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for single mode SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a
Rail Requirement
The XENPAK rail system required to mount the XENPAK module is fully defined by the MSA.
Aqueous Wash
Finisar XENPAK transponders are neither solderable nor aqueous washable and are not intended for these processes.
VI. | Regulatory Compliance |
| |
|
|
|
|
Feature |
| Standard | Comments |
ESD: |
| Class 1a (> 500 V) | |
Electrostatic Discharge to the |
|
| |
Electrical Pins (HBM) | Method 3015.7) |
| |
Immunity: |
| EN | Discharges ranging from ±2 kV to ±25 kV to |
Against Electrostatic Discharge | IEC | the front end / faceplate / receptacle cause no | |
(ESD) to the Module Receptacle |
| damage to module (under recommended | |
|
|
| conditions). |
Immunity: |
| EN | With a field strength of 10 V/m, noise |
Against Radio Frequency | IEC | frequency ranges from 10 MHz to 2 GHz. No | |
Electromagnetic Field |
| effect on module performance between the | |
|
|
| specification limits. |
Emission: |
| FCC 47 CFR | Noise frequency range: |
Electromagnetic Interference | Part 15, Class B | 30 MHz to 40 GHz | |
(EMI) |
| EN 55022 Class B | Radiated emission does not exceed specified |
|
| CISPR 22 | limits when measured inside a shielding |
|
|
| enclosure with MSA conform cutout. |
© Finisar Corporation – October 2008 | Rev B | Page 8 |