FTLX1461E2 Product Specification – October 2008
Receive Functions
Reserved |
| O | 38 | Reserved For Future Use | |
Reserved |
| O | 39 | Reserved For Future Use | |
RX LANE 0+ | O | 41 | Module XAUI Output Lane 0+ | ||
RX LANE 0– | Internally biased | O | 42 | Module XAUI Output Lane 0– | |
| differential |
|
|
| |
RX LANE 1+ | O | 44 | Module XAUI Output Lane 1+ | ||
XAUI | |||||
RX LANE 1– | O | 45 | Module XAUI Output Lane 1– | ||
RX LANE 2+ |
| O | 47 | Module XAUI Output Lane 2+ | |
RX LANE 2– |
| O | 48 | Module XAUI Output Lane 2– | |
RX LANE 3+ |
| O | 50 | Module XAUI Output Lane 3+ | |
RX LANE 3– |
| O | 51 | Module XAUI Output Lane 3– | |
DC Power |
|
|
|
| |
GND | 0 V DC |
| 1, 2, 3, 33, 34, | Ground connection for signal ground | |
|
|
| 35, 36, 37, 40, | on the module | |
|
|
| 43, 46, 49, 52, |
| |
|
|
| 53, 54, 57, 60, |
| |
|
|
| 63, 66, 69, 70 |
| |
APS | +1.2 V |
| 7, 8, 28, 29 | Input from Adaptive Power Supply | |
APS SENSE | +1.2 V |
| 27 | APS Sense Output. Connected to the | |
|
|
|
| APS input inside transponder. | |
APS SET |
|
| 25 | Feedback input from APS. | |
|
|
|
| Connected to GND through a 1180Ω | |
|
|
|
| resistor inside the transponder. | |
3.3 V | +3.3 V DC |
| 5, 6, 30, 31 | DC Power Input, +3.3 V DC, | |
|
|
|
| Nominal | |
5.0 V | +5.0 V DC |
| 4, 32 | DC Power Input, +5.0 V DC, | |
|
|
|
| Nominal | |
Reserved |
|
| 26 | Reserved for APD. | |
Reserved |
|
| 13 | Reserved. |
© Finisar Corporation – October 2008 | Rev B | Page 3 |