4Distant end Eb/No (Software versions >=2.12)

Valid only when the AUPC feature is active, this provides an output of the distant end Eb/No. Scaling is as for option 1 (Local Rx Eb/No).

5AUPC Delta Power (Software versions >=2.12)

Valid only when the AUPC feature is active, this provides an output of the local power adjustments in made in order to maintain the distant Eb/No. Scaling is 0V=-25dB, 10V=+25dB, with 0.1dB resolution. Practically it limits to between the upper and lower AUPC delta limits set by the operator (ie although scaled to ±25dB, it may practically vary only to +3 -1dB if those are the upper and lower AUPC delta limits set).