Text on Display

Description / Cause / Notes

Relays

To Terr

To Sat

Other

 

 

 

 

 

TX TRAFFIC FAULTS (Top line of display)

Tx Warn: Reconfiguring Tx path

Tx Fault: <line> off, terr <DTE/DCE> not ready

Tx Traffic Faults: Tx OK LED Off and Tx Traffic (prompt) relay.

The modem is reconfiguring the Tx path (after a user parameter change).

<line> depends on the interface in use (eg RS422 DCE=”TR”, V.35=”DTR”). This is a DC co ntrol line which is used to indicate the terrestrial equipment is functioning properly. The <line> switching off may be user set to cause this fault or be ignored (Change, Terr-Int, Control Lines).See note 5.

TOpt

TFOpt

Tx Fault: <line> off, nothing to send

<line> depends on the interface in use (eg RS422 DCE=”RS”, V.35=”RTS”). This is a handshak e line which is used to indicate the terrestrial equipment has data to send. The <line> switching off may be user set to cause this fault or be ignored (Change, Terr-Int, Control Lines). The Modem can be set to mute the Tx carrier if this line is off (Change, Tx, Mod, Carrier). If carrier is set to mute when this line is off but this line is set to ignore, then there is no alarm when this line mutes the carrier. See note 5

TOpt

CMOpt

TF

Tx Fault: No clock from interface

Tx Fault: Data input is all ones (AIS)

Tx Fault: No Incoming Octet Timing

Tx Fault: Frame sync lost on Tx input

Tx Fault: TS16 MF sync lost on Tx input

The modem is set to use the “Tx Clock In” (Change, Tx, Clocking), but no clock is being provided. The clock generation will use the internal clock as a backup to maintain the carrier and any framing/ESC integrity. Check the data connector is attached and for activity on the clock input lines

The data supplied to the modem is all ones (AIS). This is normally used to indicate an upstream equipment fault, it is not a modem fault. See note 4

This message is only displayed if a 64kbps G.703 card is fitted. It indicates the card has detected that there is no incoming octet timing on the G.703 signal. The monitoring of this octet timing may be enabled and disabled with Change, Terr-Int, Card Specific.

The modem only detects frame sync when the Drop mux is active (or 2048k IBS G.732 0% overhead mode is enabled). Check the bearer type is specified correctly (Change, Tx, Baseband, Drop). This normally only occurs if either there are significant errors on the terrestrial link, or if it is supplied with AIS and the modem is set to ignore AIS. Check that the AIS detector is not disabled with Change, User-Opt, Operation, Actions, AIS. ALSO there is an option to make the modem re-seek frame sync if CRC sync is lost (Change, User-Opt, Operation, Terrestrial, PCM Bearer CRC, CRC/Frame Acq’). Check the modem is not set to expect a CRC and forcing frame re-acquisition if CRC is lost, but there is no CRC on the PCM signal.

The modem only seeks TS16 Multiframe sync when the Tx baseband is set to use the Drop mux in a G.732 mode and CAS signalling has been selected (or 2048k IBS G.732 0% overhead mode with CAS is enabled). Check that a CAS multiframe is present on the PCM signal applied to the modem (ie terrestrial TS16 contains the 16 frame multiframe sequence).

T

TOpt

TOpt

T

T

TB

TBOpt

TB

(TB/TE) Note 1

SA,SC

SAOpt,

SCOpt

SA,SC

SC

TF

P300H

P300 Series Installation and Operating Handbook

Page 217

Page 217
Image 217
Paradise P300 specifications Text on Display Description / Cause / Notes